PROCEDURE
INSPECT THERMOSTAT
Immerse the thermostat in water, and then gradually heat the water.
Check the valve opening temperature of the thermostat.
| Standard Valve Opening Temperature |
|---|
| 100 °C (212 °F) |
If the valve opening temperature is not as specified, replace the thermostat.
Check that the valve is fully closed when the thermostat is at a low temperature (below 88°C (190°F)).
If not fully closed, replace the thermostat.