CONTINUOUSLY VARIABLE TRANSAXLE SYSTEM Pattern Select Switch Sport Mode Circuit

DESCRIPTION

The ECM memory contains the programs for the normal and sport shift patterns.

By following the programs corresponding to the signals from the No. 1 pattern select switch assembly, the park/neutral position switch and other various sensors, the ECM switches the shift control solenoid valves on and off, and controls the transaxle gear ratio.

WIRING DIAGRAM

A002OOZE12
*a No. 1 Pattern Select Switch Assembly

CAUTION / NOTICE / HINT

Note


  • Perform initialization when parts related to the continuously variable transaxle are replaced Click here.

  • Check that no DTCs are stored after performing initialization Click here.

PROCEDURE


  1. INSPECT NO. 1 PATTERN SELECT SWITCH ASSEMBLY


    1. A002NVCE26
      Text in Illustration
      *a

      Component without harness connected

      (No. 1 Pattern Select Switch Assembly)

      Remove the No. 1 pattern select switch assembly Click here.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      4 (MSW1) - 1 (MSW2) No. 1 pattern select switch on Below 1 Ω
      4 (MSW1) - 1 (MSW2) No. 1 pattern select switch off 10 kΩ or higher

    NG
    OK
  2. CHECK HARNESS AND CONNECTOR (NO. 1 PATTERN SELECT SWITCH ASSEMBLY - BODY GROUND)


    1. A002M2XE02
      Text in Illustration
      *a

      Front view of wire harness connector

      (to No. 1 Pattern Select Switch Assembly)

      Disconnect the No. 1 pattern select switch assembly connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      H94-1 (MSW2) - Body ground Always Below 1 Ω

    NG
    OK
  3. CHECK HARNESS AND CONNECTOR (NO. 1 PATTERN SELECT SWITCH ASSEMBLY - ECM)


    1. A002NN1E02
      Text in Illustration
      *a

      Front view of wire harness connector

      (to ECM)

      Disconnect the ECM connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      A76-57 (PWMS) - Body ground No. 1 pattern select switch on Below 1 Ω
      A76-57 (PWMS) - Body ground No. 1 pattern select switch off 10 kΩ or higher

    NG
    OK
  4. REPLACE ECM


    1. Replace the ECM Click here


    NEXT