TAIL GATE INSPECTION

PROCEDURE


  1. INSPECT BACK DOOR REMOTE CONTROL ASSEMBLY

    A01WVO5E01
    *1 Component without harness connected: (Back Door Remote Control Assembly)
    *2 Not pulled (Off)
    *3 Pulled (On)

    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      1 - 2 Back door remote control is pulled (On) Below 1 Ω
      1 - 2 Back door remote control is not pulled (Off) 10 kΩ or higher

      If the result is not as specified, replace the back door remote control assembly.

  2. INSPECT LOWER TAIL GATE LOCK ASSEMBLY LH


    1. A01WSK9E05

      Operation check:


      1. Set the lower tail gate lock LH to the full-latch position.

      2. Apply battery voltage and check operation of the lower tail gate lock motor LH.

        OK
        Measurement Condition Specified Condition

        Battery positive (+) → Terminal 6 (ACT-)

        Battery negative (-) → Terminal 5 (ACT+)

        Latch turns to open-latch position

        If the result is not as specified, replace the lower tail gate lock assembly LH.

      3. Set the lower tail gate lock LH to the half-latch position.

      4. Apply battery voltage and check operation of the lower tail gate lock motor LH.

        OK
        Measurement Condition Specified Condition

        Battery positive (+) → Terminal 5 (ACT+)

        Battery negative (-) → Terminal 6 (ACT-)

        Latch turns to over-latch position

        If the result is not as specified, replace the lower tail gate lock assembly LH.

    2. A01WSK9E16

      Resistance check:


      1. Measure the resistance according of the value(s) in the table below.

        Standard Resistance
        Close Position Switch
        Tester Connection Condition Specified Condition
        7 (HND) - 8 (GND) Over-latch Below 1 Ω
        7 (HND) - 8 (GND) Full-latch 10 kΩ or higher
        7 (HND) - 8 (GND) Half-latch 10 kΩ or higher
        7 (HND) - 8 (GND) Open-latch 10 kΩ or higher

        If the result is not as specified, replace the lower tail gate lock assembly LH.

        Lower Tail Gate Courtesy Switch
        Tester Connection Condition Specified Condition
        2 (FUL) - 3 (E1) Over-latch 10 kΩ or higher
        2 (FUL) - 3 (E1) Full-latch 10 kΩ or higher
        2 (FUL) - 3 (E1) Half-latch Below 1 Ω
        2 (FUL) - 3 (E1) Open-latch Below 1 Ω

        If the result is not as specified, replace the lower tail gate lock assembly LH.

        Half-latch Switch
        Tester Connection Condition Specified Condition
        1 (HAF) - 3 (E1) Over-latch 10 kΩ or higher
        1 (HAF) - 3 (E1) Full-latch Below 1 Ω
        1 (HAF) - 3 (E1) Half-latch 10 kΩ or higher
        1 (HAF) - 3 (E1) Open-latch Below 1 Ω

        If the result is not as specified, replace the lower tail gate lock assembly LH.

        Pawl Switch
        Tester Connection Condition Specified Condition
        4 (POL) - 3 (E1) Over-latch 10 kΩ or higher
        4 (POL) - 3 (E1) Full-latch Below 1 Ω
        4 (POL) - 3 (E1) Half-latch Below 1 Ω
        4 (POL) - 3 (E1) Open-latch 10 kΩ or higher

        If the result is not as specified, replace the lower tail gate lock assembly LH.

  3. INSPECT LOWER TAIL GATE LOCK ASSEMBLY RH


    1. A01WSX0E03

      Operation check:


      1. Set the lower tail gate lock RH to the full-latch position.

      2. Apply battery voltage and check operation of the lower tail gate lock motor RH.

        OK
        Measurement Condition Specified Condition

        Battery positive (+) → Terminal 6 (ACT-)

        Battery negative (-) → Terminal 5 (ACT+)

        Latch turns to open-latch position

        If the result is not as specified, replace the lower tail gate lock assembly RH.

      3. Set the lower tail gate lock RH to the half-latch position.

      4. Apply battery voltage and check operation of the lower tail gate lock motor RH.

        OK
        Measurement Condition Specified Condition

        Battery positive (+) → Terminal 5 (ACT+)

        Battery negative (-) → Terminal 6 (ACT-)

        Latch turns to over-latch position

        If the result is not as specified, replace the lower tail gate lock assembly RH.

    2. A01WSX0E12

      Resistance check:


      1. Measure the resistance according of the value(s) in the table below.

        Standard Resistance
        Close Position Switch
        Tester Connection Condition Specified Condition
        7 (HND) - 8 (GND) Over-latch Below 1 Ω
        7 (HND) - 8 (GND) Full-latch 10 kΩ or higher
        7 (HND) - 8 (GND) Half-latch 10 kΩ or higher
        7 (HND) - 8 (GND) Open-latch 10 kΩ or higher

        If the result is not as specified, replace the lower tail gate lock assembly RH.

        Lower Tail Gate Courtesy Switch
        Tester Connection Condition Specified Condition
        2 (FUL) - 3 (E1) Over-latch 10 kΩ or higher
        2 (FUL) - 3 (E1) Full-latch 10 kΩ or higher
        2 (FUL) - 3 (E1) Half-latch Below 1 Ω
        2 (FUL) - 3 (E1) Open-latch Below 1 Ω

        If the result is not as specified, replace the lower tail gate lock assembly RH.

        Half-latch Switch
        Tester Connection Condition Specified Condition
        1 (HAF) - 3 (E1) Over-latch 10 kΩ or higher
        1 (HAF) - 3 (E1) Full-latch Below 1 Ω
        1 (HAF) - 3 (E1) Half-latch 10 kΩ or higher
        1 (HAF) - 3 (E1) Open-latch Below 1 Ω

        If the result is not as specified, replace the lower tail gate lock assembly RH.

        Pawl Switch
        Tester Connection Condition Specified Condition
        4 (POL) - 3 (E1) Over-latch 10 kΩ or higher
        4 (POL) - 3 (E1) Full-latch Below 1 Ω
        4 (POL) - 3 (E1) Half-latch Below 1 Ω
        4 (POL) - 3 (E1) Open-latch 10 kΩ or higher

        If the result is not as specified, replace the lower tail gate lock assembly RH.