AIR CONDITIONING SYSTEM IG Power Source Circuit

DESCRIPTION

The main power source is supplied to the air conditioning amplifier assembly when the engine switch is on (IG). The power source is used for operating the air conditioning amplifier assembly and servo motor, etc.

WIRING DIAGRAM

B00188OE21
*a from IG1 Relay
*b A/C COMP
*c Air Conditioning Amplifier Assembly

CAUTION / NOTICE / HINT

Note

Inspect the fuses for circuits related to this system before performing the following inspection procedure.

PROCEDURE


  1. CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - BATTERY AND BODY GROUND)


    1. B00196SE02
      Text in Illustration
      *a

      Rear view of wire harness connector

      (to Air Conditioning Amplifier Assembly)

      Disconnect the air conditioning amplifier assembly connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      E36-1 (GND) - Body ground Always Below 1 Ω
    3. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Switch Condition Specified Condition
      E36-5 (IG+) - Body ground Engine switch off Below 1 V
      E36-5 (IG+) - Body ground Engine switch on (IG) 11 to 14 V

    OK
    NG