AIR CONDITIONING SYSTEM, Diagnostic DTC:B1441/41

DTC Code DTC Name
B1441/41 Air Mix Damper Control Servo Motor Circuit (Passenger Side)

DESCRIPTION


The air mix damper servo motor RH*1 or LH*2 sends pulse signals to inform the air conditioning amplifier assembly of the damper position. The air conditioning amplifier assembly activates the motor (normal or reverse) based on the signals to move the air mix damper servo motor RH*1 or LH*2 to any position. As a result, the amount of air that has passed through the evaporator and is passing through the heater core is adjusted, and the temperature of the air blowing toward the front passenger side is controlled.

Tech Tips

Confirm that no mechanical problem is present because this trouble code can be output when either a damper link or damper is mechanically locked.

DTC Code DTC Detection Condition Trouble Area
B1441/41 The air mix damper position does not change even if the air conditioning amplifier assembly operates the air mix damper servo motor.
  • Air mix damper servo motor RH*1

  • Air mix damper servo motor LH*2

  • Air conditioning harness assembly

  • Air conditioning amplifier assembly

WIRING DIAGRAM

B00190HE73

PROCEDURE


  1. READ VALUE USING GTS (AIR MIX SERVO TARG PULSE[P], AIR MIX SERVOACTUAL PULSE[P])


    • *1: for LHD

    • *2: for RHD


    1. Use the Data List to check if the air mix damper servo motor RH*1 or LH*2 is functioning properly Click here.

      Air Conditioner
      Tester Display Measurement Item/Range Normal Condition Diagnostic Note
      Air Mix Servo Targ Pulse (P) Air mix damper servo motor RH*1 or LH*2 target pulse / Min.: 128, Max.: 383

        for LHD:

      • MAX COLD: 181 (pulse)

      • MAX HOT: 263 (pulse)


        for RHD:

      • MAX COLD: 331 (pulse)

      • MAX HOT: 249 (pulse)


      • Displayed between 181 and 263 pulse (for LHD)

      • Displayed between 249 and 331 pulse (for RHD)

      • Air mix damper servo motor RH*1 or LH*2 system malfunction

      Air Mix Servo Actual Pulse(P) Air mix damper servo motor RH*1 or LH*2 actual pulse / Min.: 128, Max.: 383

        for LHD:

      • MAX COLD: 181 (pulse)

      • MAX HOT: 263 (pulse)


        for RHD:

      • MAX COLD: 331 (pulse)

      • MAX HOT: 249 (pulse)


      • Displayed between 181 and 263 pulse (for LHD)

      • Displayed between 249 and 331 pulse (for RHD)

      • Air mix damper servo motor RH*1 or LH*2 system malfunction

      OK
      When the front passenger side temperature adjustment switch is turned from MAX COLD to MAX HOT, the actual pulse changes following the target pulse.
      Result
      Result Proceed to
      Target pulse changes but actual pulse does not change) A
      Target pulse and actual pulse do not change B
      Actual pulse changes following the target pulse (When troubleshooting according to the DTC) C
      Actual pulse changes following the target pulse (When troubleshooting according to Problem Symptoms Table) D

    B
    C
    D
    A
  2. CHECK AIR MIX DAMPER SERVO MOTOR (for Front Passenger Side)


    1. for LHD:


      1. Replace the air mix damper servo motor RH Click here.

    2. for RHD:


      1. Replace the air mix damper servo motor LH Click here.

        Tech Tips

        Since the servo motor cannot be inspected while it is removed from the vehicle, replace the servo motor with a normal one.

    3. Clear the DTCs Click here.

    4. Check for DTCs Click here.

      OK
      DTC B1441/41 is not output.

    OK
    NG
  3. CHECK AIR CONDITIONING HARNESS ASSEMBLY


    1. Replace the air conditioning harness assembly with a new or known good one Click here.

    2. Clear the DTCs Click here.

    3. Check for DTCs Click here.

      OK
      DTC B1441/41 is not output.

    OK
    NG
  4. CHECK FOR DTC


    1. Clear the DTCs Click here.

    2. Check for DTCs Click here.

      OK
      DTC B1441/41 is not output.

    OK
    NG