ROOM LIGHT(for Center) INSPECTION

PROCEDURE


  1. REMOVE NO. 1 ROOM LIGHT ASSEMBLY

    A01WQ1FE02
    Text in Illustration
    *a

    Component without harness connected

    (No. 1 Room Light Assembly)


    1. Apply battery voltage to the connector and check the light illumination condition.

      OK
      Measurement Condition Condition Specified Condition

      Battery positive (+) → 1 (MPR)

      Battery negative (-) → 9 (E)

      Always Illuminates (RH side)

      Battery positive (+) → 3 (MPL)

      Battery negative (-) → 9 (E)

      Always Illuminates (LH side)

      If the result is not as specified, replace the No. 1 room light assembly.