DESCRIPTION
This circuit is the power source circuit for the combination meter. This circuit provides 2 power source types: one is a constant power source mainly used as a backup power source, and the other is a power source mainly used for signal transmission. The constant power source is mainly used as a backup power source for the meter CPU. However, it is also used for communication. If a voltage of 12 V is not applied to terminal IG+ when the engine switch is on (IG), indicators will not operate.
WIRING DIAGRAM
PROCEDURE
INSPECT FUSE (METER, MPX-B NO. 2)
Remove the METER and MPX-B NO. 2 fuses from the engine room relay block.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||
|---|---|---|---|---|---|---|---|
|
| NG |
|
REPLACE FUSE |
| OK |
|
CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - BATTERY AND BODY GROUND)
Disconnect the E120 meter connector.
Measure the resistance and voltage according to the value(s) in the tables below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
| Standard Voltage | ||||||||
|---|---|---|---|---|---|---|---|---|
|
| OK |
|
REPLACE COMBINATION METER ASSEMBLY Click here |
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |