DOOR CONTROL SWITCH INSPECTION

PROCEDURE


  1. INSPECT DOOR CONTROL SWITCH ASSEMBLY


    1. A01WRHYE07

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      12 (L) - 5 (E) Lock Below 1 Ω

      12 (L) - 5 (E)

      7 (UL) - 5 (E)

      Off 10 kΩ or higher
      7 (UL) - 5(E) Unlock Below 1 Ω

      If the result is not as specified, replace the control switch assembly.

    2. Apply battery voltage to the switch connector and check that the indicator (LED) illuminates.

      OK
      Measurement Condition Specified Condition

      Battery positive (+) → 1 (ILL+)

      Battery negative (-) → 3 (ILL-)

      Indicator (LED) illuminates

      If the result is not as specified, replace the control switch assembly.