PROCEDURE
INSPECT VANE PUMP SHAFT AND BUSH IN VANE PUMP FRONT HOUSING
Using a micrometer, measure the outer diameter [a] of the vane pump shaft.
Using a vernier caliper, measure the inner diameter [b] of the vane pump front housing bush.
Calculate the oil clearance.
Oil clearance = Inner diameter of the bush [b] - Outer diameter of the shaft [a]
| Maximum oil clearance |
|---|
| 0.07 mm (0.00276 in.) |
If the oil clearance is more than the maximum, replace the vane pump assembly.
INSPECT VANE PUMP ROTOR AND VANE PUMP PLATE
| *1 | Thickness |
Using a micrometer, measure the thickness of the vane pump plates.
| Standard thickness |
|---|
| 1.405 to 1.411 mm (0.0553 to 0.0556 in.) |
If the thickness is not as specified, replace the vane pump assembly.
| *1 | Feeler Gauge |
Using a feeler gauge, measure the clearance between the side face of the vane pump rotor groove and the vane pump plate.
| Maximum clearance |
|---|
| 0.03 mm (0.00118 in.) |
If the clearance is more than the maximum, replace the vane pump assembly.
INSPECT TOTAL PRELOAD
Check that the pump rotates smoothly without abnormal noise.
Temporarily install a service bolt.
| Recommended service bolt |
|---|
| Thread diameter |
| 10 mm (0.394 in.) |
| Thread pitch |
| 1.25 mm (0.0492 in.) |
| Bolt length |
| 50 mm (1.97 in.) |
| *1 | Service Bolt |
Using a torque wrench, measure the pump rotating torque.
| Standard rotating torque |
|---|
| 0.3 N*m (3 kgf*cm, 2 in.*lbf) or less |
If the rotating torque is not as specified, check the vane pump housing oil seal.