ABSORBER CONTROL SWITCH INSPECTION

PROCEDURE


  1. INSPECT INTEGRATION CONTROL AND PANEL ASSEMBLY


    1. B0019C2E10

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Height Control Switch
      Tester Connection Switch Condition Specified Condition
      10 (LO) - 1 (E) Down button of height control switch is pushed. Below 1 Ω
      Height control switch is not pushed or up button is pushed. 10 kΩ or higher
      9 (HI) - 1 (E) Up button of height control switch is pushed. Below 1 Ω
      Height control switch is not pushed or down button is pushed. 10 kΩ or higher
      Height Control OFF Switch
      Tester Connection Switch Condition Specified Condition
      22 (N) - 1 (E) Height control OFF switch is pushed. Below 1 Ω
      Height control OFF switch is not pushed. 10 kΩ or higher

      If the result is not as specified, replace the integration control and panel assembly.