PROCEDURE
INSTALL SUSPENSION CONTROL PUMP ACCUMULATOR ASSEMBLY
Install the accumulator with the 3 nuts.
INSTALL NO. 7 HEIGHT CONTROL TUBE
| *1 | Fulcrum Length |
| *2 | Union Nut Wrench |
Using a union nut wrench, install the No. 7 control tube to the control valve and accumulator.
Tech Tips
Use a torque wrench with a fulcrum length of 300 mm (11.8 in.).
The torque value for use with a union nut wrench is effective when the union nut wrench is parallel to the torque wrench.
INSTALL CENTER EXHAUST PIPE ASSEMBLY
INSTALL TAILPIPE ASSEMBLY
BLEED AIR FROM SUSPENSION FLUID
CHECK FLUID LEVEL IN RESERVOIR
INSPECT FOR SUSPENSION FLUID LEAK
INSTALL HEIGHT CONTROL UNIT INSULATOR
CHECK FOR EXHAUST GAS LEAK
If gas is leaking, tighten the areas necessary to stop the leak. Replace damaged parts as necessary.