HEIGHT CONTROL ACCUMULATOR INSTALLATION

PROCEDURE


  1. INSTALL SUSPENSION CONTROL PUMP ACCUMULATOR ASSEMBLY

    A01WQVF

    1. Install the accumulator with the 3 nuts.

      Torque:
      31 N*m  { 316 kgf*cm, 23 ft.*lbf }
  2. INSTALL NO. 7 HEIGHT CONTROL TUBE

    A01WWJJE01
    *1 Fulcrum Length
    *2 Union Nut Wrench

    1. Using a union nut wrench, install the No. 7 control tube to the control valve and accumulator.

      Torque:
      without union nut wrench
      15 N*m  { 155 kgf*cm, 11 ft.*lbf }
      with union nut wrench
      14 N*m  { 143 kgf*cm, 10 ft.*lbf }

      Tech Tips


      • Use a torque wrench with a fulcrum length of 300 mm (11.8 in.).

      • The torque value for use with a union nut wrench is effective when the union nut wrench is parallel to the torque wrench.

  3. INSTALL CENTER EXHAUST PIPE ASSEMBLY

    Click here

  4. INSTALL TAILPIPE ASSEMBLY

    Click here

  5. BLEED AIR FROM SUSPENSION FLUID

    Click here

  6. CHECK FLUID LEVEL IN RESERVOIR

    Click here

  7. INSPECT FOR SUSPENSION FLUID LEAK

    Click here

  8. INSTALL HEIGHT CONTROL UNIT INSULATOR

    Click here

  9. CHECK FOR EXHAUST GAS LEAK


    • If gas is leaking, tighten the areas necessary to stop the leak. Replace damaged parts as necessary.