CENTER DIFFERENTIAL LOCK SWITCH INSPECTION

PROCEDURE


  1. REMOVE INTEGRATION CONTROL AND PANEL ASSEMBLY


  2. INSPECT INTEGRATION CONTROL AND PANEL ASSEMBLY (CENTER DIFFERENTIAL LOCK SWITCH)


    1. B0019C2E24
      Text in Illustration
      *a

      Component without harness connected

      (Integration Control and Panel Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      1 (E) - 18 (CPU)

      Mode switch being pushed and held

      (CTR DIFF)

      Below 1 Ω

      Mode switch not pushed

      (CTR DIFF)

      10 kΩ or higher

      If the result is not as specified, replace the integration control and panel assembly.

  3. INSTALL INTEGRATION CONTROL AND PANEL ASSEMBLY