DPF SWITCH(for DPF) INSPECTION

PROCEDURE


  1. INSPECT NO. 2 COMBINATION SWITCH ASSEMBLY


    1. A01WQU5E02

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      14 - 12 Switch OFF 10 kΩ or higher
      14 - 12 Switch ON Below 1 Ω

      If the result is not as specified, replace the No. 2 combination switch assembly.

    2. Apply battery voltage to the switch connector and check that the No. 2 combination switch assembly illuminates.

      OK
      Measurement Condition Specified Condition
      Apply battery voltage to terminal 3 (+) and 5 (-) Mark illumination illuminates

      If the result is not as specified, replace the No. 2 combination switch assembly.