EXHAUST GAS TEMPERATURE SENSOR(for DPF) INSPECTION

PROCEDURE


  1. INSPECT EXHAUST GAS TEMPERATURE SENSOR


    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 50°C (122°F) 42 to 68 kΩ

      Tech Tips

      The temperature indicated under "Condition" is the temperature of the exhaust gas temperature sensor.

      If the result is not as specified, replace the exhaust gas temperature sensor.

  2. INSPECT NO. 2 EXHAUST GAS TEMPERATURE SENSOR


    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 50°C (122°F) 42 to 68 kΩ

      Tech Tips

      The temperature indicated under "Condition" is the temperature of the exhaust gas temperature sensor.

      If the result is not as specified, replace the No. 2 exhaust gas temperature sensor.

  3. INSPECT NO. 3 EXHAUST GAS TEMPERATURE SENSOR


    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 50°C (122°F) 42 to 68 kΩ

      Tech Tips

      The temperature indicated under "Condition" is the temperature of the exhaust gas temperature sensor.

      If the result is not as specified, replace the No. 3 exhaust gas temperature sensor.

  4. INSPECT NO. 4 EXHAUST GAS TEMPERATURE SENSOR


    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 50°C (122°F) 42 to 68 kΩ

      Tech Tips

      The temperature indicated under "Condition" is the temperature of the exhaust gas temperature sensor.

      If the result is not as specified, replace the No. 4 exhaust gas temperature sensor.