AIR INJECTION DRIVER(w/ Secondary Air Injection System) INSTALLATION

PROCEDURE


  1. INSTALL AIR INJECTION CONTROL DRIVER ASSEMBLY


    1. A01WVVM

      Install the air injection control driver with the 3 bolts.

      Torque:
      8.0 N*m  { 82 kgf*cm, 71 in.*lbf }
    2. A01WSVS

      Connect the 4 air injection control driver connectors.

    3. A01WVNM

      Connect the wire harness clamp.

    4. Connect the ground wire with the bolt.

      Torque: