PROCEDURE
INSPECT FRONT ENGINE MOUNTING INSULATOR
Visually check the front engine mounting insulator for leaks.
If the fluid leaks, replace the front engine mounting insulator.
INSPECT FRONT ENGINE MOUNTING INSULATOR
| *a | Vacuum |
Connect a vacuum pump to the front engine mounting insulator.
Using the vacuum pump, apply a vacuum of 80 kPa (600 mmHg. 25 in.Hg) and wait for 1 minute.
Check that there is no change in the needle movement of the vacuum pump gauge.
If the result is not as specified, replace the front engine mounting insulator.