AUTOMATIC HIGH BEAM MAIN SWITCH INSPECTION

PROCEDURE


  1. INSPECT COMBINATION SWITCH ASSEMBLY


    1. Inspect the automatic high beam main switch.


      1. A01WUZCE01
        Text in Illustration
        *a

        Component without harness connected

        (Combination Switch Assembly)

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Switch Condition Specified Condition
        E125-1 (+B) - E125-10 (E) Automatic high beam main switch off 10 kΩ or higher
        Automatic high beam main switch on Below 1 Ω

        If the result is not as specified, replace the combination switch assembly.

    2. Check the illumination.


      1. A01WW1EE01
        Text in Illustration
        *a

        Component without harness connected

        (Combination Switch Assembly)

        Apply battery voltage to the connector and check the LED illumination conditions.

        OK
        Measurement Condition Specified Condition

        Battery positive (+) → E125-7 (ILL+)

        Battery negative (-) → E125-12 (ILL-)

        Illuminates

        If the result is not as specified, replace the combination switch assembly.