LIGHTING SYSTEM Hazard Warning Switch Circuit

DESCRIPTION

The combination meter assembly receives hazard warning signal switch information signals and illuminates the hazard warning lights.

WIRING DIAGRAM

B0018K9E23

PROCEDURE


  1. READ VALUE USING GTS (HAZARD FLASHER SWITCH)


    1. Using the GTS, read the Data List Click here.

      Combination Meter
      Tester Display Measurement Item/Range Normal Condition Diagnostic Note
      Hazard Flasher Switch Hazard warning signal switch signal / ON or OFF

      ON: Hazard warning signal switch on

      OFF: Hazard warning signal switch off

      -
      OK
      Normal conditions listed above are displayed.

    OK
    NG
  2. INSPECT MULTI-MEDIA MODULE RECEIVER ASSEMBLY (HAZARD WARNING SIGNAL SWITCH)


    1. Remove the multi-media module receiver (hazard warning signal switch) Click here.

    2. Inspect the multi-media module receiver (hazard warning signal switch) Click here.


    NG
    OK
  3. CHECK HARNESS AND CONNECTOR (MULTI-MEDIA MODULE RECEIVER (HAZARD WARNING SIGNAL SWITCH) - COMBINATION METER ASSEMBLY)


    1. Disconnect the F77 multi-media module receiver (hazard warning signal switch) connector.

    2. Disconnect the E121 combination meter assembly connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      F77-10 (LJB) - E121-5 (HAZM) Always Below 1 Ω
      F77-9 (HAZ) - E121-11 (HZSW) Always Below 1 Ω
      F77-10 (LJB) - Body ground Always 10 kΩ or higher
      F77-9 (HAZ) - Body ground Always 10 kΩ or higher

    OK
    NG