ECD SYSTEM(w/ DPF) ECM Power Source Circuit

DESCRIPTION

When the ignition switch is turned to ON, the battery voltage is applied to the IGSW terminal of the ECM. The output signal from the MREL terminal of the ECM causes current to flow to the coil, closing the contacts of the integration relay (EFI MAIN NO. 1 relay) and supplying power to terminal +B of the ECM.

WIRING DIAGRAM

A01WPB2E02

CAUTION / NOTICE / HINT

Note

After replacing the ECM, the new ECM needs registration (See page ) and initialization Click here.

PROCEDURE


  1. INSPECT INTEGRATION RELAY (POWER SOURCE)

    A01WQ30E02
    *a

    Front view of wire harness connector

    (Integration relay)


    1. Remove the integration relay from the engine room relay block.

    2. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      1M-1 - Body ground Always 11 to 14 V

    NG
    OK
  2. CHECK HARNESS AND CONNECTOR (INTEGRATION RELAY - BODY GROUND)


    1. Remove the integration relay from the engine room relay block.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1Q-4 - Body ground Always Below 1 Ω

    NG
    OK
  3. INSPECT INTEGRATION RELAY (EFI MAIN NO. 1 AND IG2 MAIN)


    1. Inspect the integration relay Click here.


    NG
    OK
  4. CHECK HARNESS AND CONNECTOR (INTEGRATION RELAY - ECM)


    1. Remove the integration relay from the engine room relay block.

    2. Disconnect the ECM connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      for LHD
      Tester Connection Condition Specified Condition
      A85-44 (MREL) - 1Q-8 Always Below 1 Ω
      A85-2 (+B) - 1Q-11 Always Below 1 Ω
      A85-1 (+B2) - 1Q-11 Always Below 1 Ω
      A85-44 (MREL) or 1Q-8 - Body ground Always 10 kΩ or higher
      A85-2 (+B) or 1Q-11 - Body ground Always 10 kΩ or higher
      A85-1 (+B2) or 1Q-11 - Body ground Always 10 kΩ or higher
      for RHD
      Tester Connection Condition Specified Condition
      A86-44 (MREL) - 1Q-8 Always Below 1 Ω
      A86-2 (+B) - 1Q-11 Always Below 1 Ω
      A86-1 (+B2) - 1Q-11 Always Below 1 Ω
      A86-44 (MREL) or 1Q-8 - Body ground Always 10 kΩ or higher
      A86-2 (+B) or 1Q-11 - Body ground Always 10 kΩ or higher
      A86-1 (+B2) or 1Q-11 - Body ground Always 10 kΩ or higher

    NG
    OK
  5. CHECK HARNESS AND CONNECTOR (ECM - BODY GROUND)


    1. Disconnect the ECM connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      for LHD
      Tester Connection Condition Specified Condition
      C110-81 - Body ground Always Below 1 Ω
      for RHD
      Tester Connection Condition Specified Condition
      C138-81 - Body ground Always Below 1 Ω

    NG
    OK
  6. INSPECT ECM (IGSW VOLTAGE)

    A01WQGYE01

    1. Disconnect the ECM connectors.

    2. Turn the ignition switch to ON.

    3. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      for LHD
      Tester Connection Switch Condition Specified Condition
      A85-28 (IGSW) - C110-81 (E1) Ignition switch ON 11 to 14 V
      for RHD
      Tester Connection Switch Condition Specified Condition
      A86-28 (IGSW) - C138-81 (E1) Ignition switch ON 11 to 14 V

    OK
    NG
  7. CHECK HARNESS AND CONNECTOR (INTEGRATION RELAY - ECM)


    1. Disconnect the ECM connector.

    2. Remove the integration relay from the engine room relay block.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      for LHD
      Tester Connection Condition Specified Condition
      A85-28 (IGSW) - 1N-7 Always Below 1 Ω
      A85-28 (IGSW) or 1N-7 - Body ground Always 10 kΩ or higher
      for RHD
      Tester Connection Condition Specified Condition
      A86-28 (IGSW) - 1N-7 Always Below 1 Ω
      A86-28 (IGSW) or 1N-7 - Body ground Always 10 kΩ or higher

    NG
    OK
  8. CHECK ENTRY AND START SYSTEM (SMART KEY ECU ASSEMBLY - INTEGRATION RELAY)


    1. Disconnect the smart key ECU assembly connector.

    2. Disconnect the integration relay connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      E149-3 (IG1D) - 1P-2 Always Below 1 Ω
      E149-3 (IG1D) or 1P-2 - Body ground Always 10 kΩ or higher

    OK
    NG