SUSPENSION CONTROL SERVICE DATA

Height Control Pump and Motor
Measurement Condition Specified Condition

Battery positive (+) → Terminal 2

Battery negative (-) → Terminal 1

Motor operating sound heard
Damping Force Control Actuator for (Front side)
Tester Connection Condition Specified Condition
RH Side 1 (FAR+) - 2 (E FR) Always 12.0 to 13.6 kΩ
3 (FBR-) - 2 (E FR)
4 (FAR-) - 2 (E FR)
5 (FBR+) - 2 (E FR)
LH Side 1 (FAL+) - 2 (E FL) Always 12.0 to 13.6 kΩ
3 (FBL-) - 2 (E FL)
4 (FAL-) - 2 (E FL)
5 (FBL+) - 2 (E FL)
Front Spring Rate Switching Valve
Tester Connection Condition Specified Condition
for RH 1 (CRFR) - 2 (SLB) 20°C (68°F) 4.58 to 5.02 Ω
for LH 1 (CRFL) - 2 (SLB)
Damping Force Control Actuator for (Rear side)
Tester Connection Condition Specified Condition
RH Side 1 (RAR+) - 2 (E RR) Always 12.0 to 13.6 kΩ
3 (RBR-) - 2 (E RR)
4 (RAR-) - 2 (E RR)
5 (RBR+) - 2 (E RR)
LH Side 1 (RAL+) - 2 (E RL) Always 12.0 to 13.6 kΩ
3 (RBL-) - 2 (E RL)
4 (RAL-) - 2 (E RL)
5 (RBL+) - 2 (E RL)
Height Control Sensor (for Front Side)
Tester Connection Condition Specified Condition
for RH 2 (SHFR) - 1 (SHG) Max. HI Approx. 4.1 V
Normal Approx. 2.25 V
Min. LO Approx. 0.45 V
for LH 2 (SHFL) - 1 (SHG) Max. HI Approx. 4.1 V
Normal Approx. 2.25 V
Min. LO Approx. 0.45 V
Height Control Sensor (for Rear Side)
Tester Connection Condition Specified Condition
for RH 2 (SHRR) - 3 (SHG) Max. HI Approx. 4.1 V
Normal Approx. 2.25 V
Min. LO Approx. 0.45 V
for LH 2 (SHRL) - 3 (SHG) Max. HI Approx. 4.1 V
Normal Approx. 2.25 V
Min. LO Approx. 0.45 V
Front Acceleration Sensor
Tester Connection Condition Specified Condition
for RH 1 (SGFR) - 2 (SGG) Sensor is not tilted Approx. 2.0 to 2.5 V
Sensor is tilted Change between approx. 0.9 to 2.3 V
for LH 1 (SGFL) - 2 (SGG) Sensor is not tilted Approx. 2.0 to 2.5 V
Sensor is tilted Change between approx. 0.9 to 2.3 V
Relay
Tester Connection Condition Specified Condition
3 - 5 Battery voltage is not applied to terminals 1 and 2 10 kΩ or higher
Battery voltage is applied to terminals 1 and 2 Below 1 Ω
Height Control Switch
Tester Connection Switch Condition Specified Condition
10 (LO) - 1 (E) Down button of height control switch is pushed. Below 1 Ω
Height control switch is not pushed or up button is pushed. 10 kΩ or higher
9 (HI) - 1 (E) Up button of height control switch is pushed. Below 1 Ω
Height control switch is not pushed or down button is pushed. 10 kΩ or higher
Height Control OFF Switch
Tester Connection Switch Condition Specified Condition
22 (N) - 1 (E) Height control OFF switch is pushed. Below 1 Ω
Height control OFF switch is not pushed. 10 kΩ or higher
Access Mode Switch
Tester Connection Switch Condition Specified Condition
for LHD 6 (ECU1) - 16 (GND) Pushed and held Below 1 Ω
Not pushed 10 kΩ or higher
for RHD 3 (ECU1) - 3 (GND) Pushed and held Below 1 Ω
Not pushed 10 kΩ or higher