1VD-FTV FUEL SERVICE DATA

Fuel injector (w/o DPF) Standard resistance Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 0.85 to 1.05 Ω
Fuel supply pump Suction control valve Standard resistance Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 1.9 to 2.3 Ω
Standard thrust clearance 0.05 to 0.30 mm (0.00197 to 0.0118 in.)
Common rail Fuel pressure sensor Standard resistance Tester Connection Condition Specified Condition
1 - 2 25°C (77°F) 16.4 kΩ or less
2 - 3 25°C (77°F) 3 kΩ or less
Pressure discharge valve (w/ DPF) Standard resistance 1 - 2 25°C (68°F) 0.96 to 1.16 Ω
Fuel filter Level warning switch Standard resistance Tester Connection Condition Specified Condition
1 - 2 Float upper end position Below 1 Ω
1 - 2 Float lower end position 1 MΩ or higher
Clogging switch Standard resistance Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) Below 1 Ω
Fuel temperature sensor Standard resistance Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 2.32 to 2.59 kΩ
1 - 2 80°C (176°F) 0.310 to 0.326 kΩ
Fuel pump (for Double Tank Type) Standard resistance Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 0.2 to 3.0 Ω
Fuel sender gauge assembly Standard Voltage Tester Connection Condition Specified Condition
2 (FE) - 3 (FR) Float position is F (upper) 4.25 to 4.61 V*
Float position is E (lower) 0.34 to 0.70 V*
Fuel sender gauge assembly (for Fuel Sub Tank) Standard Voltage Tester Connection Condition Specified Condition
2 (FE) - 3 (FR) Float position is F (upper) 4.25 to 4.61 V*
Float position is E (lower) 0.34 to 0.70 V*

*: The output voltage changes depending on the voltage applied to the terminals.