KNOCK SENSOR INSTALLATION

PROCEDURE


  1. INSTALL KNOCK SENSOR

    A01WW6NE02

    1. Install the 4 sensors with the 4 bolts so that the sensors are angled as shown in the illustration.

      Torque:
      20 N*m  { 204 kgf*cm, 15 ft.*lbf }

      Note

      The acceptable installation angle of the sensor is between 10° upward and downward from the horizontal position.

    2. Connect the 4 sensor connectors.

  2. INSTALL NO. 1 ENGINE COVER

    Click here

  3. INSTALL NO. 2 ENGINE COVER

    Click here

  4. INSTALL INTAKE MANIFOLD


    1. Install the intake manifold Click here.