AIRBAG SYSTEM SRS Warning Light Remains ON

DESCRIPTION

The SRS warning light is located in the combination meter assembly.

When the SRS is normal, the SRS warning light comes on for approximately 6 seconds after the power switch is turned from off to on (IG), and then goes off automatically.

If there is a malfunction in the SRS, the SRS warning light comes on to inform the driver of a problem.

When terminals TC and CG of the DLC3 are connected, DTCs are output by the blinking of the SRS warning light.

The SRS is equipped with a voltage-increase circuit (DC-DC converter) in the center airbag sensor assembly in case the source voltage drops.

When the auxiliary battery voltage drops, the voltage-increase circuit (DC-DC converter) functions to increase the voltage of the SRS to normal voltage.

A malfunction in this circuit is not recorded in the center airbag sensor assembly. The SRS warning light automatically goes off when the source voltage returns to normal.

The signal to illuminate the SRS warning light is transmitted from the center airbag sensor assembly to the combination meter assembly through the CAN communication system.

WIRING DIAGRAM

A000RPPE10

CAUTION / NOTICE / HINT

Note


  • After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work Click here.

  • When disconnecting the cable from the negative (-) auxiliary battery terminal while performing repairs, some systems need to be initialized after the cable is reconnected Click here.

  • Inspect the fuses for circuits related to this system before performing the following inspection procedure.

PROCEDURE


  1. CHECK CAN COMMUNICATION SYSTEM


    1. Check if a CAN communication DTC is output.


      Result
      Result Proceed to
      DTCs are output (for LHD) A
      DTCs are output (for RHD) B
      DTC is not output C

    A
    B
    C
  2. CHECK AUXILIARY BATTERY


    1. Measure the voltage of the auxiliary battery.

      Standard voltage
      11 to 14 V

    NG
    OK
  3. CHECK CONNECTION OF CONNECTORS


    1. Turn the power switch off.

    2. Disconnect the cable from the negative (-) auxiliary battery terminal, and wait for at least 90 seconds.

    3. Check that the connectors are properly connected to the center airbag sensor assembly and combination meter assembly.

      OK
      The connectors are properly connected.

    NG
    OK
  4. CHECK HARNESS AND CONNECTOR (SOURCE VOLTAGE OF CENTER AIRBAG SENSOR ASSEMBLY)


    1. A000ONIE03
      Text in Illustration
      *a

      Rear view of wire harness connector

      (to Center Airbag Sensor Assembly)

      Disconnect the connectors from the center airbag sensor assembly.

    2. Connect the cable to the negative (-) auxiliary battery terminal, and wait for at least 2 seconds.

    3. Turn the power switch on (IG).

    4. Operate all the components of the electrical system (defogger, wipers, headlights, heater blower, etc.).

    5. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Switch Condition Specified Condition
      N52-21 (IG2) - N52-25 (E1) Power switch on (IG) 11 to 14 V
      N52-21 (IG2) - N52-26 (E2) Power switch on (IG) 11 to 14 V

    NG
    OK
  5. CHECK HARNESS AND CONNECTOR (SOURCE VOLTAGE OF COMBINATION METER ASSEMBLY)


    1. A000RIHE02
      Text in Illustration
      *a

      Front view of wire harness connector

      (to Combination Meter Assembly)

      Disconnect the cable from the negative (-) auxiliary battery terminal, and wait for at least 90 seconds.

    2. Disconnect the N40 connector from the combination meter assembly.

    3. Connect the cable to the negative (-) auxiliary battery terminal, and wait for at least 2 seconds.

    4. Turn the power switch on (IG).

    5. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      N40-21 (IG+) - N40-31 (ES) Power switch on (IG) 11 to 14 V
      N40-22 (B) - N40-31 (ES) Always 11 to 14 V

    NG
    OK
  6. CHECK SRS WARNING LIGHT (SHORT TO GROUND)


    1. Turn the power switch off.

    2. Disconnect the cable from the negative (-) auxiliary battery terminal, and wait for at least 90 seconds.

    3. Connect the connector to the combination meter assembly.

    4. Connect the cable to the negative (-) auxiliary battery terminal, and wait for at least 2 seconds.

    5. Turn the power switch on (IG).

    6. Check the SRS warning light condition.

      OK
      After the primary check period, the SRS warning light goes off for approximately 10 seconds and then remains on.

      Tech Tips

      The primary check period is approximately 6 seconds after the power switch is turned to on (IG).


    OK
    NG