SHIFT LEVER INSPECTION

PROCEDURE


  1. INSPECT TRANSMISSION FLOOR SHIFT ASSEMBLY

    Tech Tips

    If the results of the following inspections are as specified but a malfunction has occurred, replace the transmission floor shift assembly.


    1. Disconnect the shift lock control ECU connector.

    2. A000QRLE06
      Text in Illustration
      *a Front view of wire harness connector (to Shift Lock Control ECU)

      Measure the voltage according to the value(s) in the table below.

      Tech Tips

      Do not disconnect the shift lock control ECU connector.

      Standard Voltage
      Tester Connection Condition Specified Condition
      4 (STP) - Body ground Brake pedal depressed 11 to 14 V
      Brake pedal released Below 1 V
      5 (IG) - Body ground Power switch on (IG) 11 to 14 V
      Power switch off Below 1 V

      If the result is not as specified, repair or replace the shift lock control ECU wire harness.

    3. A000QRLE07
      Text in Illustration
      *a Front view of wire harness connector (to Shift Lock Control ECU)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 (E) - Body ground Always Below 1 V

      If the result is not as specified, repair or replace the shift lock control ECU wire harness.

  2. INSPECT TRANSMISSION CONTROL SWITCH


    1. Disconnect the transmission control switch connector.

    2. A000RBKE38
      Text in Illustration
      *a Component without harness connected (Transmission Control Switch)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      for LHD
      Tester Connection Condition Specified Condition
      1 (SFTD) - 2 (E) Shift lever held in "-" Below 1 Ω
      Shift lever not held in "-" 10 kΩ or higher
      3 (SFTU) - 2 (E) Shift lever held in "+" Below 1 Ω
      Shift lever not held in "+" 10 kΩ or higher
      4 (IG) - 5 (S) Shift lever in S, "+" or "-" Below 1 Ω
      Shift lever not in S, "+" or "-" 10 kΩ or higher
      for RHD
      Tester Connection Condition Specified Condition
      1 (SFTU) - 2 (E) Shift lever held in "+" Below 1 Ω
      Shift lever not held in "+" 10 kΩ or higher
      3 (SFTD) - 2 (E) Shift lever held in "-" Below 1 Ω
      Shift lever not held in "-" 10 kΩ or higher
      4 (IG) - 5 (S) Shift lever in S, "+" or "-" Below 1 Ω
      Shift lever not in S, "+" or "-" 10 kΩ or higher

      If the result is not as specified, replace the transmission floor shift assembly.