TRANSMISSION WIRE INSPECTION

PROCEDURE


  1. INSPECT TRANSMISSION WIRE


    1. A000NE7E25
      Text in Illustration
      *a

      Component without harness connected

      (Transmission Wire)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection ATF Temperature Specified Condition
      9 (THO) - 3 (E) 10°C (50°F) 5.0 to 8.0 kΩ
      9 (THO) - 3 (E) 110°C (230°F) 0.22 to 0.28 Ω

      Tech Tips

      If the resistance is not within the specified range at any of the ATF temperatures shown in the table above, the driveability of the vehicle may decrease.