SHIFT LEVER POSITION SENSOR INSPECTION

PROCEDURE


  1. INSPECT SHIFT LEVER POSITION SENSOR


    1. A000S6LE83
      Text in Illustration
      *a

      Component without harness connected

      (Shift Lever Position Sensor)

      Measure the resistance according to the value(s) in the table below when the shift lever is moved to each position.

      Standard Resistance
      Tester Connection Condition Specified Condition
      7 - 1 Shift Lever in P Below 1 Ω
      7 - 4 Below 1 Ω
      7 - 3, 2, 5, 9, 6 10 kΩ or higher*1
      7 - 5 Shift Lever in R Below 1 Ω
      7 - 4 Below 1 Ω
      7 - 6 Below 1 Ω
      7 - 3, 2, 1, 9 10 kΩ or higher*1
      7 - 2 Shift Lever in N Below 1 Ω
      7 - 4 Below 1 Ω
      7 - 3, 1, 5, 9, 6 10 kΩ or higher
      7 - 3 Shift Lever in D Below 1 Ω
      7 -9 Below 1 Ω
      7 - 4 Below 1 Ω
      7 - 2, 1, 5, 6 10 kΩ or higher*1

      Note

      *1: The resistance between terminals 7 (+B) and 2 (N) should be between 4.2 and 5.2 kΩ.