RELAY INSPECTION

PROCEDURE


  1. INSPECT COOLING FAN RELAY (FAN NO. 1)


    1. A000MZPE03

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3 - 5 Battery voltage is not applied between terminals 1 and 2 10 kΩ or higher
      3 - 5 Battery voltage is applied between terminals 1 and 2 Below 1 Ω

      If the result is not as specified, replace the cooling fan relay.