INJECTOR DRIVER INSTALLATION

PROCEDURE


  1. INSTALL INJECTOR DRIVER

    Note

    Be careful not to drop or strike the injector driver.


    1. Install the injector driver to the intake manifold with the 2 bolts and 2 nuts.

      Torque:
      10 N*m  { 102 kgf*cm, 7 ft.*lbf }
    2. A000QT4E02
      Text in Illustration
      *a Lock Lever
      *b Connector (with Lock)

      Connect the 2 injector driver connectors.

    3. Connect the connector (with lock) to the injector driver and move the lock lever as shown in the illustration to engage the lock.

      Note

      Securely connect the connector (with lock) to the injector driver and engage the lock lever.

  2. INSTALL NO. 1 INVERTER RESERVE TANK BRACKET (for LHD)

    Click here

  3. CONNECT INVERTER RESERVE TANK ASSEMBLY (for LHD)


    1. Connect the inverter reserve tank assembly to the No. 1 inverter reserve tank bracket with the 2 bolts.

      Torque:
      13 N*m  { 127 kgf*cm, 9 ft.*lbf }
    2. Attach the clamp to connect the No. 3 inverter cooling hose to the No. 1 inverter reserve tank bracket.

    3. Attach the clamp to connect the inlet hybrid water pump hose to the No. 1 inverter reserve tank bracket.

    4. Attach the clamp to connect the wire harness to the inverter reserve tank assembly.

  4. INSTALL AIR CLEANER CASE SUB-ASSEMBLY (for LHD)

    Click here

  5. INSTALL AIR CLEANER FILTER ELEMENT SUB-ASSEMBLY (for LHD)

    Click here

  6. INSTALL INLET NO. 1 AIR CLEANER (for LHD)

    Click here

  7. INSTALL COOL AIR INTAKE DUCT SEAL (for LHD)

  8. INSTALL AIR CLEANER HOSE ASSEMBLY

    Click here

  9. CONNECT CABLE TO NEGATIVE AUXILIARY BATTERY TERMINAL

    Note

    When disconnecting the cable, some systems need to be initialized after the cable is reconnected Click here.