DRIVE BELT REMOVAL

PROCEDURE


  1. REMOVE ENGINE ROOM SIDE COVER

    Click here

  2. REMOVE COOL AIR INTAKE DUCT SEAL

    Click here

  3. REMOVE NO. 1 AIR CLEANER INLET

    Click here

  4. REMOVE NO. 1 ENGINE COVER SUB-ASSEMBLY

    Click here

  5. REMOVE FAN AND GENERATOR V BELT


    1. Prepare a clean durable piece of cloth and fold it several times.

      Tech Tips

      Fold the cloth several times to make it thicker.

    2. A000OAX

      Pass the cloth under the fan and generator V belt between the crankshaft pulley assembly and engine water pump assembly as shown in the illustration.

      Note

      Position the cloth so that the part closest to the engine is longer.

    3. A000NJP

      Slightly rotate the crankshaft pulley assembly clockwise so that the cloth is pulled between the fan and generator V belt and engine water pump assembly.

      Note

      Do not allow the cloth to be pulled further than the top center of the engine water pump assembly.

    4. A000NXM

      Fold the cloth over the fan and generator V belt and pull it as shown in the illustration while gradually rotating the crankshaft pulley assembly clockwise.

      Note

      Pull the cloth until the upper part of the fan and generator V belt comes off the engine water pump assembly.

    5. A000OHR

      Check that the upper part of the fan and generator V belt is off the engine water pump assembly, then rotate the crankshaft pulley assembly clockwise to remove the fan and generator V belt.