WATER PUMP WITH MOTOR REMOVAL

PROCEDURE


  1. REMOVE ENGINE ROOM SIDE COVER

    Click here

  2. REMOVE COOL AIR INTAKE DUCT SEAL

    Click here

  3. REMOVE NO. 1 AIR CLEANER INLET

    Click here

  4. REMOVE ENGINE UNDER COVER

    Click here

  5. REMOVE FRONT SUSPENSION MEMBER BRACE

    Click here

  6. REMOVE NO. 2 ENGINE UNDER COVER

    Click here

  7. DRAIN COOLANT (for Inverter)

    Click here

  8. REMOVE HV WATER PUMP BRACKET SUB-ASSEMBLY


    1. A000N9I

      Detach the clamp and disconnect the connector.

    2. A000PUA

      for LHD:

      Disconnect the 2 water hoses.

      Note

      Apply insulating tape to the pipe and in the disconnected hose or cover the pipe and hose with plastic bags to prevent entry of foreign matter.

    3. A000QN2

      for RHD:

      Detach the clamp and disconnect the 2 water hoses.

      Note

      Apply insulating tape to the connectors of the wire harness and inverter water pump with motor to prevent the entry of coolant.

    4. A000OVK

      Remove the bolt and HV water pump bracket.

  9. REMOVE INVERTER WATER PUMP WITH MOTOR ASSEMBLY


    1. A000Q13

      Remove the 3 bolts.