| DTC Code | DTC Name |
|---|---|
| P0A80-123 | Replace Hybrid Battery Pack |
DESCRIPTION
| *1 | Battery Block |
| *2 | Battery Module |
| *3 | Battery Smart Unit |
The HV battery uses nickel metal-hydride batteries and does not require external charging. The power management control ECU controls the SOC (state of charge) of the HV battery at a constant level during driving. The HV battery is composed of 40 modules, and each module consists of six 1.2 V cells in series. The battery smart unit monitors battery block voltage at 20 locations. Each battery block is composed of 2 modules in a set.
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
|---|---|---|---|
| P0A80 | 123 | Difference in voltage between battery blocks is larger than the standard (2 trip detection) |
|
Tech Tips
P0A80-123 will not be set unless the vehicle is driven for approximately 10 minutes after clearing the DTC.
In order to ensure HV battery performance, appropriate cooling performance must be maintained. Perform the following items as necessary. If cooling performance has decreased and "Maintenance required for hybrid battery cooling parts at your dealer" is displayed on the multi-information display, make sure to perform the following items:
- Make sure the air intake port is not blocked.
- Make sure there are no gaps between the connecting parts of the ducts.
- Clean the filter of the No. 1 or No. 6 hybrid battery intake duct.
Clear the DTCs to reset the learning values even if no DTCs are stored.
CAUTION / NOTICE / HINT
CAUTION:
When disposing of an HV battery, make sure to return it through an authorized collection agent who is capable of handling it safely. If the HV battery is returned via the manufacturer specified route, it will be returned properly and in a safe manner by an authorized collection agent.
PROCEDURE
CHECK DTC OUTPUT (HYBRID CONTROL)
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Read output DTCs.
| Result | ||||||
|---|---|---|---|---|---|---|
|
Turn the power switch off.
| B |
|
GO TO DTC CHART (P0AFC-123) Click here |
| A |
|
CHECK FREEZE FRAME DATA
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Read output DTCs.
Using the GTS, make a note of the freeze frame data item "Battery Block Vol -V01 to V20".
Compare the freeze frame data item "Battery Block Vol -V01 to V20" values with those shown in the following combination tables.
| Circuit A Battery Block | Circuit B Battery Block | Condition |
|---|---|---|
| Battery Block Vol - V01 (VB1) | Battery Block Vol - V02 (VB2) | "Battery Block Vol - V01" - "Battery Block Vol - V02" = 0.3 V or more |
| Battery Block Vol - V04 (VB4) | Battery Block Vol - V03 (VB3) | "Battery Block Vol - V04" - "Battery Block Vol - V03" = 0.3 V or more |
| Battery Block Vol - V05 (VB5) | Battery Block Vol - V06 (VB6) | "Battery Block Vol - V05" - "Battery Block Vol - V06" = 0.3 V or more |
| Battery Block Vol - V08 (VB8) | Battery Block Vol - V07 (VB7) | "Battery Block Vol - V08" - "Battery Block Vol - V07" = 0.3 V or more |
| Battery Block Vol - V09 (VB9) | Battery Block Vol - V10 (VB10) | "Battery Block Vol - V09" - "Battery Block Vol - V10" = 0.3 V or more |
| Battery Block Vol - V12 (VB12) | Battery Block Vol - V11 (VB11) | "Battery Block Vol - V12" - "Battery Block Vol - V11" = 0.3 V or more |
| Battery Block Vol - V13 (VB13) | Battery Block Vol - V14 (VB14) | "Battery Block Vol - V13" - "Battery Block Vol - V14" = 0.3 V or more |
| Battery Block Vol - V16 (VB16) | Battery Block Vol - V15 (VB15) | "Battery Block Vol - V16" - "Battery Block Vol - V15" = 0.3 V or more |
| Battery Block Vol - V17 (VB17) | Battery Block Vol - V18 (VB18) | "Battery Block Vol - V17" - "Battery Block Vol - V18" = 0.3 V or more |
| Battery Block Vol - V20 (VB20) | Battery Block Vol - V19 (VB19) | "Battery Block Vol - V20" - "Battery Block Vol - V19" = 0.3 V or more |
| Circuit A Battery Block | Circuit B Battery Block | Condition |
|---|---|---|
| Battery Block Vol - V01 (VB1) | Battery Block Vol - V02 (VB2) | "Battery Block Vol - V02" - "Battery Block Vol - V01" = 0.3 V or more |
| Battery Block Vol - V04 (VB4) | Battery Block Vol - V03 (VB3) | "Battery Block Vol - V03" - "Battery Block Vol - V04" = 0.3 V or more |
| Battery Block Vol - V05 (VB5) | Battery Block Vol - V06 (VB6) | "Battery Block Vol - V06" - "Battery Block Vol - V05" = 0.3 V or more |
| Battery Block Vol - V08 (VB8) | Battery Block Vol - V07 (VB7) | "Battery Block Vol - V07" - "Battery Block Vol - V08" = 0.3 V or more |
| Battery Block Vol - V09 (VB9) | Battery Block Vol - V10 (VB10) | Battery Block Vol - V10" - "Battery Block Vol - V09" = 0.3 V or more |
| Battery Block Vol - V12 (VB12) | Battery Block Vol - V11 (VB11) | "Battery Block Vol - V11" - "Battery Block Vol - V12" = 0.3 V or more |
| Battery Block Vol - V13 (VB13) | Battery Block Vol - V14 (VB14) | "Battery Block Vol - V14" - "Battery Block Vol - V13" = 0.3 V or more |
| Battery Block Vol - V16 (VB16) | Battery Block Vol - V15 (VB15) | "Battery Block Vol - V15" - "Battery Block Vol - V16" = 0.3 V or more |
| Battery Block Vol - V17 (VB17) | Battery Block Vol - V18 (VB18) | "Battery Block Vol - V17" - "Battery Block Vol - V18" = 0.3 V or more |
| Battery Block Vol - V20 (VB20) | Battery Block Vol - V19 (VB19) | "Battery Block Vol - V20" - "Battery Block Vol - V19" = 0.3 V or more |
Tech Tips
When an internal malfunction occurs in the battery smart unit, this symptom (difference in voltage of 0.3 V or more for all 10 pairs of blocks) will occur.
| Result | |||||||
|---|---|---|---|---|---|---|---|
|
Turn the power switch off.
| A |
|
REPLACE BATTERY SMART UNIT Click here |
| B |
|
REPLACE HV BATTERY Click here |