| DTC Code | DTC Name |
|---|---|
| P0B3D-123 | Hybrid Battery Voltage Sensor "A" Circuit Low |
| P0B42-123 | Hybrid Battery Voltage Sensor "B" Circuit Low |
| P0B47-123 | Hybrid Battery Voltage Sensor "C" Circuit Low |
| P0B4C-123 | Hybrid Battery Voltage Sensor "D" Circuit Low |
| P0B51-123 | Hybrid Battery Voltage Sensor "E" Circuit Low |
| P0B56-123 | Hybrid Battery Voltage Sensor "F" Circuit Low |
| P0B5B-123 | Hybrid Battery Voltage Sensor "G" Circuit Low |
| P0B60-123 | Hybrid Battery Voltage Sensor "H" Circuit Low |
| P0B65-123 | Hybrid Battery Voltage Sensor "I" Circuit Low |
| P0B6A-123 | Hybrid Battery Voltage Sensor "J" Circuit Low |
| P0B6F-123 | Hybrid Battery Voltage Sensor "K" Circuit Low |
| P0B74-123 | Hybrid Battery Voltage Sensor "L" Circuit Low |
| P0B79-123 | Hybrid Battery Voltage Sensor "M" Circuit Low |
| P0B7E-123 | Hybrid Battery Voltage Sensor "N" Circuit Low |
| P0B83-123 | Hybrid Battery Voltage Sensor "O" Circuit Low |
| P0B88-123 | Hybrid Battery Voltage Sensor "P" Circuit Low |
| P0B8D-123 | Hybrid Battery Voltage Sensor "Q" Circuit Low |
| P0B92-123 | Hybrid Battery Voltage Sensor "R" Circuit Low |
| P0B97-123 | Hybrid Battery Voltage Sensor "S" Circuit Low |
| P0B9C-123 | Hybrid Battery Voltage Sensor "T" Circuit Low |
| P0BA1-123 | Hybrid Battery Voltage Sensor "U" Circuit Low |
| P308A-123 | Hybrid Battery Voltage Sensor All Circuits Low |
DESCRIPTION
Refer to the description for DTC P0A80-123 Click here.
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
|---|---|---|---|
| P0B3D P0B42 P0B47 P0B4C P0B51 P0B56 P0B5B P0B60 P0B65 P0B6A P0B6F P0B74 P0B79 P0B7E P0B83 P0B88 P0B8D P0B92 P0B97 P0B9C P0BA1 P308A |
123 | Each battery block voltage becomes less than 2.5 V (open) (1 trip detection) |
|
Tech Tips
Values smaller than 2.0 V may not be shown in the Data List because a fail-safe value is substituted.
Hybrid battery voltage sensor in the DTC titles refers to the battery smart unit.
CAUTION / NOTICE / HINT
CAUTION:
Before inspecting the high-voltage system, take safety precautions to prevent electrical shocks, such as wearing insulated gloves and removing the service plug grip. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
After removing the service plug grip, wait at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work Click here.
Tech Tips
At least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
When disposing of an HV battery, make sure to return it through an authorized collection agent who is capable of handling it safely. If the HV battery is returned via the manufacturer specified route, it will be returned properly and in a safe manner by an authorized collection agent.
Note
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work Click here.
PROCEDURE
CHECK FOR DTCS (HYBRID CONTROL)
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Read output DTCs Click here.
| Result | ||||||
|---|---|---|---|---|---|---|
|
Turn the power switch off.
Disconnect the GTS from the DLC3.
| B |
|
GO TO DTC CHART (HYBRID BATTERY SYSTEM) Click here |
| A |
|
CHECK CONNECTOR CONNECTION CONDITION
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the No. 4 hybrid vehicle battery carrier bracket sub-assembly Click here.
Check the connections of the connector of the battery smart unit Click here.
| OK |
|---|
| The connectors are connected securely and there are no contact problems. |
Install the No. 4 hybrid vehicle battery carrier bracket sub-assembly.
| NG |
|
CONNECT SECURELY |
| OK |
|
REPLACE BATTERY SMART UNIT
Replace the battery smart unit Click here.
| NEXT |
|
CLEAR DTC (HV)
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Clear the DTCs and freeze frame data Click here.
Perform a road test to charge and discharge the HV battery.
Disconnect the GTS from the DLC3.
| NEXT |
|
RECONFIRM DTC OUTPUT (HV)
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Read output DTCs Click here.
| Result | ||||||
|---|---|---|---|---|---|---|
|
Turn the power switch off.
Disconnect the GTS from the DLC3.
| A |
|
RETURN TO NORMAL OPERATION |
| B |
|
REPLACE HV BATTERY Click here |