| DTC Code | DTC Name |
|---|---|
| P0A93-346 | Inverter Cooling System Performance |
DESCRIPTION
The inverter converts the high-voltage direct current of the HV battery into the alternating current for MG1 and MG2. The inverter generates heat during the conversion process. Therefore, the inverter is cooled by a special cooling system consisting of the inverter water pump with motor assembly, the cooling fan, and a radiator. This cooling system is independent of the engine cooling system. The power management control ECU monitors the inverter water pump with motor assembly, cooling fan, and cooling system, and detects the following malfunctions.
| *A | for LHD | *B | for RHD |
| *1 | Inverter Water Pump with Motor Assembly | *2 | Inverter Reserve Tank Assembly |
| *3 | Inverter with Converter Assembly | *4 | Radiator Assembly (HV) |
| *5 | Hybrid Vehicle Transmission Assembly | - | - |
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
|---|---|---|---|
| P0A93 | 346 | Inverter cooling system malfunction (HV cooling malfunction) |
|
CAUTION / NOTICE / HINT
CAUTION:
Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work Click here.
Tech Tips
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
Note
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work Click here.
If DTC P0A78-284, 286, P0A7A-322, 324, P0A94-553 or 557 is output, replace the inverter with converter assembly after this inspection.
Tech Tips
After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
Perform a road test according to the freeze frame data "Vehicle Spd" for approximately 15 minutes. During the road test, check Data List items "Inverter Coolant Water Temperature", "Inverter Temp- (MG2)", "Inverter Temp- (MG1)", "DC/DC Cnv Temp (Upper)", " DC/DC Cnv Temp (Lower)" and "Engine Coolant Temp" to prevent the relevant parts from overheating.
PROCEDURE
CHECK VEHICLE CONDITION
Make sure that the front side of the radiator grille is not blocked with anything.
Ask the customer if the front side of the radiator grille was blocked with anything.
| Result | Proceed to |
|---|---|
| Not blocked. | A |
| Is/was blocked. | B |
Tech Tips
If the radiator grille is blocked, the inverter coolant temperature will increase and this DTC may be stored.
| B |
|
IF EQUIPPED, EXPLAIN TO CUSTOMER THAT OPTIONAL COMPONENTS WILL BE REMOVED |
| A |
|
CHECK DTC OUTPUT (HYBRID CONTROL)
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Check if DTCs are output.
| Result | ||||||
|---|---|---|---|---|---|---|
|
| DTC No. | Relevant Diagnosis |
|---|---|
| P0A02-719 | Motor Electronics Coolant Temperature Sensor Circuit Low |
| P0A03-720 | Motor Electronics Coolant Temperature Sensor Circuit High |
| P0C73-776 | Motor Electronics Coolant Pump "A" Control Performance |
| P314A-828 | Inverter Coolant Pump Speed Signal |
Tech Tips
P0A93-346 may be output due to a malfunction which also causes DTCs in the preceding table to be output. In this case, first troubleshoot the output DTCs in the preceding table. Then, perform a test to attempt to reproduce the problems, and check that no DTCs are output.
Turn the power switch off.
| B |
|
GO TO DTC CHART (HYBRID CONTROL SYSTEM) Click here |
| A |
|
CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Check the connector connections and contact pressure of the low voltage connectors of the inverter with converter assembly Click here.
Note
Before disconnecting the connector, confirm that it is properly connected by checking that the locking claws are engaged and that the connector cannot be pulled out.
| *A | for LHD | *B | for RHD |
| OK |
|---|
| The connectors are connected securely and there are no contact pressure problems. |
Tech Tips
When connecting the connector, insert it with the locking lever in the raised position. Rotate the lever downward and make sure that the connector is pulled into its socket. When the locking lever is in its fully closed position, a click will be heard as its locking claws engage. After the click is heard, pull up on the connector to confirm that it is properly connected.
| NG |
|
CONNECT SECURELY |
| OK |
|
CHECK QUANTITY OF HV COOLANT
Check the HV coolant level in the inverter reserve tank.
Check for HV coolant leaks.
| Result | Proceed to |
|---|---|
| No leaks are found and coolant level in the inverter reserve tank assembly is above the low line. | A |
| No leaks are found and coolant level in the inverter reserve tank assembly is below the low line. | B |
| HV coolant leaks are evident. | C |
Note
The inverter water pump with motor assembly has a protection function that activates when there is an HV coolant leak. Therefore, it is not necessary to replace the inverter water pump with motor assembly unless the cause of the HV coolant leak is the inverter water pump with motor assembly.
Tech Tips
After repairing the HV coolant leaks and adding coolant, perform the "Activate the (Inverter) Water Pump" Active Test (HV Active Test item) and the "Control the Electric Cooling Fan" Active Test (Engine Active Test item) and make sure that there are no malfunctions.
| B |
|
ADD HV COOLANT |
| C |
|
INSPECT FOR HV COOLANT LEAK AND ADD HV COOLANT |
| A |
|
CHECK COOLANT HOSE
Check if the hoses of the cooling system are kinked or clogged.
| NG |
|
REPAIR OR REPLACE COOLANT HOSE |
| OK |
|
PERFORM ACTIVE TEST USING GTS (CONTROL THE ELECTRIC COOLING FAN)
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Engine and ECT / Active Test / Control the Electric Cooling Fan.
Perform the "Control the Electric Cooling Fan" Active Test.
| OK |
|---|
| The cooling fan rotates. |
Turn the power switch off.
| NG |
|
CHECK COOLING FAN SYSTEM Click here |
| OK |
|
PERFORM ACTIVE TEST USING GTS (ACTIVATE THE (INVERTER) WATER PUMP)
Note
Be sure to perform the inspection with the auxiliary battery voltage at 11 V or more.
Tech Tips
When the auxiliary battery voltage is low, the inverter water pump with motor assembly may not operate.
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Active Test / Activate the (Inverter) Water Pump.
Select Inverter W/P Revolution in the Data List.
While performing the "Activate the (Inverter) Water Pump" Active Test, check Inverter W/P Revolution in the Data List.
| OK | ||||||
|---|---|---|---|---|---|---|
|
Tech Tips
Perform the Active Test with the inverter coolant temperature between -15 and 65°C (5 to 149°F).
When the inverter water pump with motor assembly is not operating, the Data List item "Inverter W/P Revolution" displays a value lower than 625 rpm.
Turn the power switch off.
| NG |
|
CHECK CONNECTOR CONNECTION CONDITION (POWER MANAGEMENT CONTROL ECU CONNECTOR) Click here |
| OK |
|
READ VALUE USING GTS (DATA LIST)
Turn the power switch off and leave the vehicle for at least 1 hour.
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Data List / Inverter Coolant Water Temperature, Inverter Temp-(MG2), DC/DC Cnv Tmp (Upper), DC/DC Cnv Temp (Lower), Inverter Temp-(MG1).
Read the Data List.
| Result | ||||||
|---|---|---|---|---|---|---|
|
Turn the power switch off.
| B |
|
REPLACE INVERTER WITH CONVERTER ASSEMBLY Click here |
| A |
|
REPLACE HV COOLANT
Replace the HV coolant with coolant having an appropriate concentration (appropriate freeze point) for the vehicle usage conditions Click here.
| NEXT |
|
COMPLETED |
CHECK CONNECTOR CONNECTION CONDITION (POWER MANAGEMENT CONTROL ECU CONNECTOR)
| *A | for LHD |
| *B | for RHD |
Check the connector connections and contact pressure of the relevant terminals for the power management control ECU connectors Click here.
| OK |
|---|
| The connectors are connected securely and there are no contact pressure problems. |
| NG |
|
CONNECT SECURELY |
| OK |
|
CHECK CONNECTOR CONNECTION CONDITION (INVERTER WATER PUMP WITH MOTOR ASSEMBLY CONNECTOR)
Check the connector connections and contact pressure of the relevant terminals for the inverter water pump with motor assembly connector Click here.
| OK |
|---|
| The connectors are connected securely and there are no contact pressure problems. |
| NG |
|
CONNECT SECURELY |
| OK |
|
CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - INVERTER WATER PUMP WITH MOTOR ASSEMBLY)
Disconnect the connector from the power management control ECU.
Disconnect the connector from the inverter water pump with motor assembly.
Measure the resistance according to the value(s) in the table below.
| *a | Rear view of wire harness connector (to Power Management Control ECU) |
*b | Front view of wire harness connector (to Inverter Water Pump with Motor Assembly) |
| Standard Resistance (Check for Open) | ||||||
|---|---|---|---|---|---|---|
|
| Standard Resistance (Check for Short) | ||||||
|---|---|---|---|---|---|---|
|
Connect the power management control ECU connector.
Connect the inverter water pump with motor assembly connector.
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
READ VALUE USING GTS (INVERTER W/P REVOLUTION)
Note
Be sure to perform the inspection with the auxiliary battery voltage at 11 V or more.
Tech Tips
When the auxiliary battery voltage is low, the inverter water pump with motor assembly may not operate.
Connect the GTS to the DLC3.
| *1 | No. 1 Engine Room Relay Block and Junction Block Assembly |
| *2 | INV W/P Fuse |
Remove the INV W/P fuse from the No. 1 engine room relay block and junction block assembly.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Data List / Inverter W/P Revolution.
Read the Data List.
| OK | ||||||
|---|---|---|---|---|---|---|
|
Turn the power switch off.
Install the INV W/P fuse.
| NG |
|
REPLACE POWER MANAGEMENT CONTROL ECU Click here |
| OK |
|
CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - INVERTER WATER PUMP WITH MOTOR ASSEMBLY)
Disconnect the connector from the power management control ECU.
Turn the power switch on (IG).
| *a | Rear view of wire harness connector (to Power Management Control ECU) |
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
Note
Turning the power switch on (IG) with the power management control ECU connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Turn the power switch off.
Connect the power management control ECU connector.
| NG |
|
REPLACE INVERTER WATER PUMP WITHMOTOR ASSEMBLY Click here |
| OK |
|
CHECK POWER MANAGEMENT CONTROL ECU (CHECK WAVEFORM)
Turn the power switch on (IG).
| *a | Component with Harness Connected (Power Management Control ECU) |
While turning the power switch on (IG), check the waveform between the power management control ECU terminals.
| Item | Content |
|---|---|
| Terminal | A35-13 (IWP) - N91-6 (E1) |
| Equipment Setting | 5 V/DIV., 50 ms./DIV. |
| Condition | Power switch on (IG) |
| OK |
|---|
| Waveform duty ratio is between 3% and 9%. |
Turn the power switch off.
| OK |
|
REPLACE INVERTER WATER PUMP WITHMOTOR ASSEMBLY Click here |
| NG |
|
REPLACE POWER MANAGEMENT CONTROL ECU Click here |