| DTC Code | DTC Name |
|---|---|
| P0A90-251 | Drive Motor "A" Performance |
DESCRIPTION
When three-phase alternating current flows through the three-phase windings of the stator coil, a rotating magnetic field is generated in motor. The system controls the rotation of the magnetic field in accordance with the rotating position and speed of the rotor. As a result, the permanent magnets provided in the rotor are pulled in the direction of rotation, generating torque. The generated torque is almost proportional to the amount of current. The system controls motor speed by regulating the frequency of the alternating current. Furthermore, the system properly controls the rotating magnetic field and the angle of the rotor magnets in order to generate high torque in an efficient manner, even at high speeds.
Tech Tips
The term "drive motor A" indicates MG2.
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
|---|---|---|---|
| P0A90 | 251 | Motor magnetic force deterioration or same phase short circuit |
|
WIRING DIAGRAM
Refer to the wiring diagram for DTC P0AA6-526 Click here.
Refer to the wiring diagram for DTC P321E-318 Click here.
CAUTION / NOTICE / HINT
CAUTION:
Before inspecting the high-voltage system, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work Click here.
Tech Tips
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
Note
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work Click here.
PROCEDURE
CHECK DTC OUTPUT (HYBRID CONTROL)
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Check if DTCs are output.
| Result | ||||||
|---|---|---|---|---|---|---|
|
| DTC No. | Relevant Diagnosis |
|---|---|
| P06B0-163 | Sensor Power Supply "A" Circuit/Open |
| P06D6-511 | Sensor Reference Voltage "F" Circuit/Open |
| P06E6-164 | Sensor Power Supply "C" Circuit/Open |
| P0A1A-151, 166, 658, 791 | Generator Control Module |
| P0A1B-198, 786, 794 | Drive Motor "A" Control Module |
| P0A1D (all INF codes)*1 | Hybrid Powertrain Control Module |
| P0A3F-243 | Drive Motor "A" Position Sensor Circuit |
| P0A40-500 | Drive Motor "A" Position Sensor Circuit Range/Performance |
| P0A41-245 | Drive Motor "A" Position Sensor Circuit Low |
| P0A4B-253 | Generator Position Sensor Circuit |
| P0A4C-513 | Generator Position Sensor Circuit Range/Performance |
| P0A4D-255 | Generator Position Sensor Circuit Low |
| P0A51-174 | Drive Motor "A" Current Sensor Circuit |
| P0A78-202, 282 | Drive Motor "A" Inverter Performance |
| P0A90-509 | Drive Motor "A" Performance |
| P0A92-521 | Hybrid Generator Performance |
| P0A93-346 | Inverter Cooling System Performance |
| P0AA6 (all INF codes)*1 | Hybrid Battery Voltage System Isolation Fault |
| P0BEA-290 | Drive Motor "A" Phase V Current Sensor Circuit Range/Performance |
| P0BEE-298 | Drive Motor "A" Phase W Current Sensor Circuit Range/Performance |
| P0C19-306 | Drive Motor "A" Torque Delivered Performance |
| P0C76-523 | Hybrid Battery System Discharge Time Too Long |
| P0D2E-586 | Drive Motor "A" Inverter Voltage Sensor Circuit Range/Performance |
| P0D2F-266 | Drive Motor "A" Inverter Voltage Sensor Circuit Low |
| P0D30-267 | Drive Motor "A" Inverter Voltage Sensor Circuit High |
| P0E05-328 | Generator Phase V Current Sensor Circuit Range/Performance |
| P0E09-336 | Generator Phase W Current Sensor Circuit Range/Performance |
| P0E32-585 | DC/DC Converter Voltage Sensor "A" Range/Performance |
| P0E33-589 | DC/DC Converter Voltage Sensor "A" Low |
| P0E34-590 | DC/DC Converter Voltage Sensor "A" High |
| P0E71-344 | Generator Torque Delivered Performance |
| P1C2A-155 | Generator A/D Converter Circuit |
| P1C2B-192 | Drive Motor "A" A/D Converter Circuit |
| P1C2D-587 | Hybrid Battery Voltage / DC/DC Converter Voltage Correlation |
| P1C3C-294 | Drive Motor "A" Phase V Current Sensor Correlation |
| P1C3D-302 | Drive Motor "A" Phase W Current Sensor Correlation |
| P1C3E-333 | Generator Phase V Current Sensor Correlation |
| P1C3F-341 | Generator Phase W Current Sensor Correlation |
| P1C4A-288 | Drive Motor "A" Phase V Current Sensor Sub Circuit Range/Performance |
| P1C4F-296 | Drive Motor "A" Phase W Current Sensor Sub Circuit Range/Performance |
| P1C54-326 | Generator Phase V Current Sensor Sub Circuit Range/Performance |
| P1C59-334 | Generator Phase W Current Sensor Sub Circuit Range/Performance |
| P1C6D-501 | Drive Motor "A" Phase V Current Sensor Offset Range/Performance |
| P1C6E-502 | Drive Motor "A" Phase W Current Sensor Offset Range/Performance |
| P1C71-515 | Generator Phase V Current Sensor Offset Range/Performance |
| P1C72-516 | Generator Phase W Current Sensor Offset Range/Performance |
| P1C73-512 | Sensor Standard Voltage "F" Circuit/Open |
| P1CA6-156 | Generator Control Module Malfunction |
| P1CA7-193 | Drive Motor Control Module Malfunction |
| P1CAC-200 | Generator Position Sensor Angle Malfunction |
| P1CAD-168 | Drive Motor "A" Position Sensor Angle Malfunction |
| P1CAF-792 | Generator Position Sensor REF Signal Cycle Malfunction |
| P1CB0-795 | Drive Motor "A" Position Sensor REF Signal Cycle Malfunction |
| P1CB2-793 | Generator Position Sensor REF Signal Stop Malfunction |
| P1CB3-796 | Drive Motor "A" Position Sensor REF Signal Stop Malfunction |
| P3004-132 | Power Cable Malfunction |
| P3133-659 | Communication Error from Generator to Drive Motor "A" |
| P3134-661 | Communication Error from Drive Motor "A" to Generator |
Tech Tips
*1: If any INF codes are output for this DTC, refer to the corresponding diagnostic procedure.
P0A90-251 may be output due to a malfunction which causes the DTCs in the table above to be output. In this case, first troubleshoot the output DTCs in the table above. Then, perform a reproduction test to check that no DTCs are output.
Turn the power switch off.
| B |
|
GO TO DTC CHART (HYBRID CONTROL SYSTEM) Click here |
| A |
|
SIMULATION TEST
Connect the GTS to the DLC3.
Turn the power switch on (READY).
Test-drive the vehicle at a speed of 40 km/h (25 mph) for approximately 1 minute.
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Check if DTCs are output.
| Result | ||||||
|---|---|---|---|---|---|---|
|
Turn the power switch off.
| B |
|
GO TO DTC CHART (HYBRID CONTROL SYSTEM) Click here |
| A |
|
CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Check the connector connections and contact pressure of the low voltage connectors of the inverter with converter assembly Click here.
Note
Before disconnecting the connector, confirm that it is properly connected by checking that the locking claws are engaged and that the connector cannot be pulled out.
| *A | for LHD | *B | for RHD |
| OK |
|---|
| The connectors are connected securely and there are no contact pressure problems. |
Tech Tips
When connecting the connector, insert it with the locking lever in the raised position. Rotate the lever downward and make sure that the connector is pulled into its socket. When the locking lever is in its fully closed position, a click will be heard as its locking claws engage. After the click is heard, pull up on the connector to confirm that it is properly connected.
| NG |
|
CONNECT SECURELY |
| OK |
|
CHECK POWER MANAGEMENT CONTROL ECU
Turn the power switch on (IG).
| *a | Component with harness connected (Power Management Control ECU) |
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
Turn the power switch off.
| NG |
|
CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - INVERTER WITH CONVERTER ASSEMBLY) Click here |
| OK |
|
CHECK INVERTER WITH CONVERTER ASSEMBLY (MOTOR CABLE CONNECTION CONDITION)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
| *A | for LHD |
| *B | for RHD |
for Type A:
Remove the inverter terminal cover from the inverter with converter assembly.
| *A | for LHD |
| *B | for RHD |
for Type B:
Remove the inverter terminal cover from the inverter with converter assembly.
| *A | for LHD |
| *B | for RHD |
| *1 | Motor Cable |
Check that the bolts for the motor cable are tightened to the specified torque, the motor cable is connected securely, and there are no contact problems.
| Specified Condition |
|---|
| T=8.0 N*m (82 kgf*cm, 71 in.*lbf) |
Note
Make sure that the tightening torque of the bolt is between 6.4 and 9.6 N*m (65 and 98 kgf*cm, 57 and 85 in.*lbf).
Disconnect the motor cable from the inverter with converter assembly.
Check for arc marks at the terminals for the motor cable.
| Result | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||
Connect the motor cable to the inverter with converter assembly.
Install the inverter terminal cover.
| B |
|
REPLACE MALFUNCTIONING PARTS |
| C |
|
CONNECT SECURELY |
| A |
|
CHECK HYBRID VEHICLE TRANSMISSION ASSEMBLY (MG2)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
| *A | for LHD |
| *B | for RHD |
for Type A:
Remove the inverter terminal cover from the inverter with converter assembly.
| *A | for LHD |
| *B | for RHD |
for Type B:
Remove the inverter terminal cover from the inverter with converter assembly.
| *A | for LHD |
| *B | for RHD |
| *1 | Generator Cable |
| *2 | Motor Cable |
Disconnect the generator cable and motor cable from the inverter with converter assembly.
| *A | for LHD |
| *B | for RHD |
| *1 | Shield Ground |
| *a | Motor Cable (Inverter with Converter Assembly Side) |
Check MG2 for an interphase short using a milliohmmeter.
Using a milliohmmeter, measure the resistance according to the value(s) in the table below.
Tech Tips
If the MG2 temperature is high, the resistance will vary greatly from the specification. Therefore, measure the resistance at least 8 hours after the vehicle is stopped.
| Standard Resistance | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
|
Tech Tips
To correct the variation of the measured resistance due to temperature, use the following formula to calculate the resistance at 20°C (68° F).
R20 = Rt / {1 + 0.00393 X (T - 20)}
The calculation is based on the following:
R20: Resistance at 20°C (68° F) (mΩ)
Rt: Measured resistance (mΩ)
T: Temperature when the resistance is measured (°C)
Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
Note
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
| Standard Resistance | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
|
Connect the generator cable and motor cable.
Install the inverter terminal cover.
| OK |
|
REPLACE INVERTER WITH CONVERTER ASSEMBLY AND HYBRID VEHICLE TRANSMISSION ASSEMBLY |
| NG |
|
CHECK HYBRID VEHICLE TRANSMISSION ASSEMBLY (MOTOR CABLE CONNECTION CONDITION) Click here |
CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - INVERTER WITH CONVERTER ASSEMBLY)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the connector from the inverter with converter assembly.
Disconnect the connector from the power management control ECU.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
||||||
|
| *A | for LHD |
| *B | for RHD |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
| *b | Rear view of wire harness connector (to Power Management Control ECU) |
Note
Turning the power switch on (IG) with the connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||||||
|
Connect the inverter with converter assembly connector.
Connect the power management control ECU connector.
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
CHECK INVERTER WITH CONVERTER ASSEMBLY
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the connector from the inverter with converter assembly.
| *A | for LHD |
| *B | for RHD |
| *a | Component without harness connected (Inverter with Converter Assembly) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
|||||||||
|
Connect the inverter with converter assembly connector.
| OK |
|
REPLACE POWER MANAGEMENT CONTROL ECU Click here |
| NG |
|
REPLACE INVERTER WITH CONVERTER ASSEMBLY Click here |
CHECK HYBRID VEHICLE TRANSMISSION ASSEMBLY (MOTOR CABLE CONNECTION CONDITION)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the hybrid vehicle transmission assembly Click here.
Check that the bolts for the motor cable are tightened to the specified torque, the motor cable is connected securely, and there are no contact problems.
| Specified Condition |
|---|
| T=8.0 N*m (82 kgf*cm, 71 in.*lbf) |
Note
Make sure that the tightening torque of the bolt is between 6.4 and 9.6 N*m (65 and 98 kgf*cm, 57 and 85 in.*lbf).
Disconnect the motor cable from the hybrid vehicle transmission assembly.
Check for arc marks at the terminals for the motor cable.
| Result | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||
Connect the motor cable to the hybrid vehicle transmission assembly.
Install the hybrid vehicle transmission assembly.
| B |
|
REPLACE MALFUNCTIONING PARTS |
| C |
|
CONNECT SECURELY |
| A |
|
CHECK MOTOR CABLE
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the motor cable Click here.
Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
| *A | for LHD | *B | for RHD |
| *1 | Shield ground | - | - |
| *a | Motor Cable (Inverter with Converter Assembly Side) |
*b | Motor Cable (Hybrid Vehicle Transmission Assembly Side) |
Note
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
| Standard Resistance | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||
|
Note
Wrap the terminals of the motor cable with insulating tape to prevent them from coming into contact with the body ground.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||||||
|
Install the motor cable.
| OK |
|
REPLACE HYBRID VEHICLE TRANSMISSION ASSEMBLY Click here |
| NG |
|
REPLACE MOTOR CABLE Click here |