| DTC Code | DTC Name |
|---|---|
| P0A1B-547 | Drive Motor "A" Control Module |
DESCRIPTION
For a description of the boost converter Click here.
If a malfunction occurs in the boost converter, the MG ECU detects it and transmits this information to the power management control ECU.
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
|---|---|---|---|
| P0A1B | 547 | Boost converter overvoltage signal detection (overvoltage due to MG ECU malfunction) | Inverter with converter assembly |
CAUTION / NOTICE / HINT
CAUTION:
Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work Click here.
Tech Tips
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
Note
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work Click here.
PROCEDURE
CHECK DTC OUTPUT (HYBRID CONTROL)
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Check if DTCs are output.
| Result | ||||||
|---|---|---|---|---|---|---|
|
| DTC No. | Relevant Diagnosis |
|---|---|
| P06B0-163 | Sensor Power Supply "A" Circuit/Open |
| P06D6-511 | Sensor Reference Voltage "F" Circuit/Open |
| P06E6-164 | Sensor Power Supply "C" Circuit/Open |
| P0A1A-151, 166, 517, 658, 791, 809 | Generator Control Module |
| P0A1B-198, 505, 554, 786, 794, 806 | Drive Motor "A" Control Module |
| P0A1D (all INF codes)*1 | Hybrid Powertrain Control Module |
| P0A3F-243 | Drive Motor "A" Position Sensor Circuit |
| P0A40-500, 506, 556, 808 | Drive Motor "A" Position Sensor Circuit Range/Performance |
| P0A41-245 | Drive Motor "A" Position Sensor Circuit Low |
| P0A4B-253 | Generator Position Sensor Circuit |
| P0A4C-513, 518, 811 | Generator Position Sensor Circuit Range/Performance |
| P0A4D-255 | Generator Position Sensor Circuit Low |
| P0A78-287, 555, 807 | Drive Motor "A" Inverter Performance |
| P0A7A-325, 810 | Generator Inverter Performance |
| P0ADB-227 | Hybrid Battery Positive Contactor Control Circuit Low |
| P0ADC-226 | Hybrid Battery Positive Contactor Control Circuit High |
| P0ADF-229 | Hybrid Battery Negative Contactor Control Circuit Low |
| P0AE0-228 | Hybrid Battery Negative Contactor Control Circuit High |
| P0BEA-290 | Drive Motor "A" Phase V Current Sensor Circuit Range/Performance |
| P0BEE-298 | Drive Motor "A" Phase W Current Sensor Circuit Range/Performance |
| P0C76-523 | Hybrid Battery System Discharge Time Too Long |
| P0D2E-586 | Drive Motor "A" Inverter Voltage Sensor Circuit Range/Performance |
| P0D2F-266 | Drive Motor "A" Inverter Voltage Sensor Circuit Low |
| P0D30-267 | Drive Motor "A" Inverter Voltage Sensor Circuit High |
| P0E05-328 | Generator Phase V Current Sensor Circuit Range/Performance |
| P0E09-336 | Generator Phase W Current Sensor Circuit Range/Performance |
| P0E32-564, 585 | DC/DC Converter Voltage Sensor "A" Range/Performance |
| P0E33-589 | DC/DC Converter Voltage Sensor "A" Low |
| P0E34-590 | DC/DC Converter Voltage Sensor "A" High |
| P1C2A-155 | Generator A/D Converter Circuit |
| P1C2B-192 | Drive Motor "A" A/D Converter Circuit |
| P1C2D-587 | Hybrid Battery Voltage / DC/DC Converter Voltage Correlation |
| P1C3C-294 | Drive Motor "A" Phase V Current Sensor Correlation |
| P1C3D-302 | Drive Motor "A" Phase W Current Sensor Correlation |
| P1C3E-333 | Generator Phase V Current Sensor Correlation |
| P1C3F-341 | Generator Phase W Current Sensor Correlation |
| P1C4A-288 | Drive Motor "A" Phase V Current Sensor Sub Circuit Range/Performance |
| P1C4F-296 | Drive Motor "A" Phase W Current Sensor Sub Circuit Range/Performance |
| P1C54-326 | Generator Phase V Current Sensor Sub Circuit Range/Performance |
| P1C59-334 | Generator Phase W Current Sensor Sub Circuit Range/Performance |
| P1C6D-501 | Drive Motor "A" Phase V Current Sensor Offset Range/Performance |
| P1C6E-502 | Drive Motor "A" Phase W Current Sensor Offset Range/Performance |
| P1C71-515 | Generator Phase V Current Sensor Offset Range/Performance |
| P1C72-516 | Generator Phase W Current Sensor Offset Range/Performance |
| P1C73-512 | Sensor Standard Voltage "F" Circuit/Open |
| P1CA6-156 | Generator Control Module Malfunction |
| P1CA7-193 | Drive Motor Control Module Malfunction |
| P1CAC-200 | Generator Position Sensor Angle Malfunction |
| P1CAD-168 | Drive Motor "A" Position Sensor Angle Malfunction |
| P1CAF-792 | Generator Position Sensor REF Signal Cycle Malfunction |
| P1CB0-795 | Drive Motor "A" Position Sensor REF Signal Cycle Malfunction |
| P1CB2-793 | Generator Position Sensor REF Signal Stop Malfunction |
| P1CB3-796 | Drive Motor "A" Position Sensor REF Signal Stop Malfunction |
| P3004-803 | Power Cable Malfunction |
| P3133-659 | Communication Error from Generator to Drive Motor "A" |
| P3134-661 | Communication Error from Drive Motor "A" to Generator |
Tech Tips
*1: If any INF codes are output for this DTC, refer to the corresponding diagnostic procedure.
P0A1B-547 may be output due to a malfunction which also causes DTCs in the preceding table to be output. In this case, first troubleshoot the output DTCs in the preceding table. Then, perform a test to attempt to reproduce the problems, and check that no DTCs are output.
Turn the power switch off.
| B |
|
GO TO DTC CHART (HYBRID CONTROL SYSTEM) Click here |
| A |
|
CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Check the connector connections and contact pressure of the low voltage connectors of the inverter with converter assembly Click here.
Note
Before disconnecting the connector, confirm that it is properly connected by checking that the locking claws are engaged and that the connector cannot be pulled out.
| *A | for LHD | *B | for RHD |
| OK |
|---|
| The connectors are connected securely and there are no contact pressure problems. |
Tech Tips
When connecting the connector, insert it with the locking lever in the raised position. Rotate the lever downward and make sure that the connector is pulled into its socket. When the locking lever is in its fully closed position, a click will be heard as its locking claws engage. After the click is heard, pull up on the connector to confirm that it is properly connected.
| OK |
|
REPLACE INVERTER WITH CONVERTER ASSEMBLY Click here |
| NG |
|
CONNECT SECURELY |