HYBRID CONTROL SYSTEM, Diagnostic DTC:P0873-875

DTC Code DTC Name
P0873-875 Transmission Fluid Pressure Sensor / Switch "C" Circuit High

DESCRIPTION

Refer to the description for DTC P0731-871 Click here.

DTC No. INF Code DTC Detection Condition Trouble Area
P0873 875 Even when the gear has changed from 1st to 2nd and then to 1st, oil pressure switch (PB1) remains on (2-trip detection logic).
  • Wire harness or connector

  • Hybrid vehicle transmission assembly

  • Power management control ECU

  • Transmission wire

  • Oil pressure switch (PB1)

WIRING DIAGRAM

Refer to the wiring diagram for DTC P0731-871 Click here.

PROCEDURE


  1. CHECK DTC OUTPUT (HYBRID CONTROL)


    1. Connect the GTS to the DLC3.

    2. Turn the power switch on (IG).

    3. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

    4. Check if DTCs are output.

      Result
      Result Proceed to
      P0873-875 only is output. A
      Any of the following DTCs are also output. B
      DTC No. Relevant Diagnosis
      P0732-867, 868 Gear 2 Incorrect Ratio
    5. Turn the power switch off.


    B
    A
  2. CHECK CONNECTOR CONNECTION CONDITION (POWER MANAGEMENT CONTROL ECU CONNECTOR)


    1. B002B9CE01
      Text in Illustration
      *A for LHD
      *B for RHD

      Check the connector connections and contact pressure of the relevant terminals for the power management control ECU connectors Click here.

      OK
      The connectors are connected securely and there are no contact pressure problems.

    NG
    OK
  3. CHECK CONNECTOR CONNECTION CONDITION (TRANSMISSION WIRE CONNECTOR)


    1. A000SJ3

      Check the connection of the transmission wire connector Click here.

      OK
      The connector is connected securely and there are no contact problems.

    NG
    OK
  4. CHECK OIL PRESSURE SWITCH (PB1)


    1. Disconnect the connector from the power management control ECU.

    2. A000PNUE02
      Text in Illustration
      *a

      Rear view of wire harness connector

      (to Power Management Control ECU)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      A36-6 (PB1) - Body ground Power switch off 10 kΩ or higher
    3. Connect the power management control ECU connector.


    NG
    OK
  5. READ VALUE USING GTS (B1 OIL PRESSURE)


    1. A000T4NE01
      Text in Illustration
      *a

      Front view of wire harness connector

      (to Transmission Wire)

      Disconnect the transmission wire connector.

    2. Connect the GTS to the DLC3.

    3. Turn the power switch on (IG).

      Note

      Turning the power switch on (IG) with the transmission wire connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

    4. Enter the following menus: Powertrain / Hybrid Control / Data List / B1 Oil Pressure.

    5. Read the Data List.

      OK
      Tester Display Condition Specified Condition
      B1 Oil Pressure F52-11 (PB1) is connected to body ground ON
      F52-11 (PB1) is not connected to body ground OFF
    6. Turn the power switch off.

    7. Connect the transmission wire connector.


    NG
    OK
  6. CLEAR DTC


    1. Connect the GTS to the DLC3.

    2. Turn the power switch on (IG).

    3. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

    4. Read and record the DTCs and freeze frame data.

    5. Clear DTCs and freeze frame data.

    6. Turn the power switch off.


    NEXT
  7. SIMULATION TEST


    1. Connect the GTS to the DLC3.

    2. Turn the power switch on (IG).

    3. Enter the following menus: Powertrain / Hybrid Control / Active Test / Activate the Oil Pump (500rpm), Activate the Oil Pump (1000rpm).

    4. Select OPM Revolution in the Data List.

    5. Perform the "Activate the Oil Pump (500rpm)" and "Activate the Oil Pump (1000rpm)" Active Tests.

      OK
      For both the "Activate the Oil Pump (500rpm)" and "Activate the Oil Pump (1000rpm)" Active Tests, the value of "OPM Revolution" is almost the same as the corresponding Active Test speed.

      Note

      Make sure that the auxiliary battery is not discharged.

    6. Turn the power switch off.


    NG
    OK
  8. CHECK FOR INTERMITTENT PROBLEMS

    Click here


    NG
    OK
  9. CHECK FLUID LEAKS


    1. Check for fluid leaks from the hybrid vehicle transmission assembly.

      OK
      There are no fluid leaks.

    NG
    OK
  10. CHECK CONNECTOR CONNECTION CONDITION (OIL PRESSURE SWITCH (PB1))


    1. A000RQX

      Remove the oil strainer assembly Click here.

    2. Check the connection of the oil pressure switch (PB1) connector Click here.

      OK
      The connector is connected securely and there are no contact problems.
    3. Install the oil strainer assembly.


    NG
    OK
  11. CHECK TRANSMISSION WIRE


    1. Remove the oil strainer assembly Click here.

    2. A000PFHE02
      Text in Illustration
      *1 Transmission Wire
      *2 Oil Pressure Switch (PB1)

      Disconnect the connector from the transmission wire.

    3. Disconnect the connector from the oil pressure switch (PB1).

    4. Turn the power switch on (IG).

    5. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Switch Condition Specified Condition
      F52-11 (PB1) - Body ground Power switch on (IG) Below 1 V

      Note

      Turning the power switch on (IG) with the transmission wire connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

    6. Turn the power switch off.

    7. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      F52-11 (PB1) - Transmission wire oil pressure switch (PB1) side Power switch off Below 1 Ω
      F52-11 (PB1) or Transmission wire oil pressure switch (PB1) side - Body ground and other terminals Power switch off 10 kΩ or higher
    8. Connect the transmission wire connector.

    9. Connect the connector to the oil pressure switch (PB1).

    10. Install the oil strainer assembly.


    OK
    NG
  12. CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - TRANSMISSION WIRE)


    1. A000O1WE02
      Text in Illustration
      *a

      Rear view of wire harness connector

      (to Power Management Control ECU)

      *b

      Front view of wire harness connector

      (to Transmission Wire)

      Disconnect the transmission wire connector.

    2. Disconnect the connector from the power management control ECU.

    3. Turn the power switch on (IG).

    4. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Switch Condition Specified Condition
      A36-6 (PB1) - Body ground Power switch on (IG) Below 1 V

      Note

      Turning the power switch on (IG) with the power management control ECU connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

    5. Turn the power switch off.

    6. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      A36-6 (PB1) - F52-11 (PB1) Power switch off Below 1 Ω
      A36-6 (PB1) or F52-11 (PB1) - Body ground and other terminals Power switch off 10 kΩ or higher
    7. Connect the transmission wire connector.

    8. Connect the power management control ECU connector.


    NG
    OK
  13. CHECK CONNECTOR CONNECTION CONDITION (OIL PRESSURE SWITCH (PB1))


    1. A000RQX

      Remove the oil strainer assembly Click here.

    2. Check the connection of the oil pressure switch (PB1) connector Click here.

      OK
      The connector is connected securely and there are no contact problems.
    3. Install the oil strainer assembly.


    NG
    OK
  14. CHECK TRANSMISSION WIRE


    1. Remove the oil strainer assembly Click here.

    2. A000PFHE02
      Text in Illustration
      *1 Transmission Wire
      *2 Oil Pressure Switch (PB1)

      Disconnect the connector from the transmission wire.

    3. Disconnect the connector from the oil pressure switch (PB1).

    4. Turn the power switch on (IG).

    5. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Switch Condition Specified Condition
      F52-11 (PB1) - Body ground Power switch on (IG) Below 1 V

      Note

      Turning the power switch on (IG) with the transmission wire connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

    6. Turn the power switch off.

    7. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      F52-11 (PB1) - Transmission wire oil pressure switch (PB1) side Power switch off Below 1 Ω
      F52-11 (PB1) or Transmission wire oil pressure switch (PB1) side - Body ground and other terminals Power switch off 10 kΩ or higher
    8. Connect the transmission wire connector.

    9. Connect the connector to the oil pressure switch (PB1).

    10. Install the oil strainer assembly.


    OK
    NG
  15. CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - TRANSMISSION WIRE)


    1. A000O1WE02
      Text in Illustration
      *a

      Rear view of wire harness connector

      (to Power Management Control ECU)

      *b

      Front view of wire harness connector

      (to Transmission Wire)

      Disconnect the transmission wire connector.

    2. Disconnect the connector from the power management control ECU.

    3. Turn the power switch on (IG).

    4. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Switch Condition Specified Condition
      A36-6 (PB1) - Body ground Power switch on (IG) Below 1 V

      Note

      Turning the power switch on (IG) with the power management control ECU connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

    5. Turn the power switch off.

    6. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      A36-6 (PB1) - F52-11 (PB1) Power switch off Below 1 Ω
      A36-6 (PB1) or F52-11 (PB1) - Body ground and other terminals Power switch off 10 kΩ or higher
    7. Connect the power management control ECU connector.

    8. Connect the transmission wire connector.


    OK
    NG