HYBRID CONTROL SYSTEM, Diagnostic DTC:P06B0-163, P06D6-511, P06E6-164, P0A1B-786, P0A1B-794, P1C2B-192, P1C73-512, P1CA7-193, P3134-661

DTC Code DTC Name
P06B0-163 Sensor Power Supply "A" Circuit / Open
P06D6-511 Sensor Reference Voltage "F" Circuit / Open
P06E6-164 Sensor Power Supply "C" Circuit / Open
P0A1B-786 Drive Motor "A" Control Module
P0A1B-794 Drive Motor "A" Control Module
P1C2B-192 Drive Motor "A" A/D Converter Circuit
P1C73-512 Sensor Standard Voltage "F" Circuit / Open
P1CA7-193 Drive Motor Control Module Malfunction
P3134-661 Communication Error from Drive Motor "A" to Generator

DESCRIPTION

The MG ECU located in the inverter with converter assembly monitors its internal operation and it will store DTCs when it detects malfunctions. If any of the following DTCs are output, replace the inverter with converter assembly.

Tech Tips

The term "drive motor A" indicates MG2.

DTC No. INF Code DTC Detection Condition Trouble Area
P06B0 163 IPM positive power source error Inverter with converter assembly
P06D6 511 Standard voltage for analog signal offset
P06E6 164 IPM negative power source error
P0A1B 786 ALU error
794 R/D converter communication error
P1C2B 192 A/D converter error
P1C73 512 Standard voltage for analog signal error
P1CA7 193 CPU ROM-RAM error
P3134 661 Communication error (from MG2 to MG1)

PROCEDURE


  1. REPLACE INVERTER WITH CONVERTER ASSEMBLY

    Click here


    NEXT