PROCEDURE
REMOVE ENGINE ROOM SIDE COVER
REMOVE COOL AIR INTAKE DUCT SEAL
REMOVE NO. 1 AIR CLEANER INLET
REMOVE AIR CLEANER CAP WITH NO. 2 AIR CLEANER HOSE
REMOVE AIR CLEANER FILTER ELEMENT SUB-ASSEMBLY
REMOVE AIR CLEANER CASE SUB-ASSEMBLY
REMOVE ENGINE UNDER COVER
DRAIN COOLANT (for Inverter)
REMOVE HV WATER PUMP BRACKET SUB-ASSEMBLY
Detach the inverter cooling hose clamp from the inverter water pump with motor assembly.
Slide the 2 clamps and disconnect the hybrid water pump inlet hose and No. 1 hybrid water pump outlet hose from the inverter water pump with motor assembly.
Note
Apply insulating tape to the pipe and in the disconnected hose or cover the pipe and hose with plastic bags to prevent entry of foreign matter.
Detach the 2 clamps and disconnect the inverter water pump connector.
Note
Wipe off any coolant from the connectors of the wire harness and inverter water pump with motor, and apply insulating tape to protect them from coolant.
Remove the 2 bolts and HV water pump bracket sub-assembly.
REMOVE INVERTER WATER PUMP WITH MOTOR ASSEMBLY
Remove the 3 bolts and inverter water pump with motor assembly from the HV water pump bracket sub-assembly.