| DTC Code | DTC Name |
|---|---|
| P0ABF-123 | Hybrid Battery Pack Current Sensor Circuit |
| P0AC1-123 | Hybrid Battery Pack Current Sensor Circuit Low |
| P0AC2-123 | Hybrid Battery Pack Current Sensor Circuit High |
DESCRIPTION
A battery current sensor is installed to the positive (+) cable side of the HV battery and detects current flowing from the HV battery. The battery current sensor outputs voltage, which changes between 0 and 5 V according to the detected amperage, to the IB terminal of the battery voltage sensor. The battery voltage sensor sends signals to the power management control ECU. The power management control ECU determines the charging and discharging amount of the HV battery based on the received signals and calculates the SOC of the HV battery through the accumulated amperage.
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| P0ABF-123 | Power source voltage of the battery current sensor is excessively low/high. (1 trip detection logic) |
|
| P0AC1-123 | The battery current sensor output value is excessively low. (1 trip detection logic) |
|
| P0AC2-123 | The battery current sensor output value is excessively high. (1 trip detection logic) |
|
| DTC No. | Data List |
|---|---|
|
Batt Pack Current Val |
WIRING DIAGRAM
| *a | Hybrid Battery Junction Block Assembly (Battery Current Sensor) |
| *b | Battery Voltage Sensor |
CAUTION / NOTICE / HINT
CAUTION:
Before inspecting the high-voltage system, take safety precautions to prevent electrical shocks, such as wearing insulated gloves and removing the service plug grip. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work Click here.
Tech Tips
At least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
Note
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work Click here.
Tech Tips
After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
Turn the power switch on (IG) and wait for 10 seconds or more.
PROCEDURE
CHECK DTC OUTPUT (HYBRID CONTROL)
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Read output DTCs.
| Result | Proceed to |
|---|---|
| P0AFC-123 is not output. | A |
| P0AFC-123 is also output. | B |
Turn the power switch off.
| B |
|
GO TO DTC CHART (P0AFC-123) Click here |
| A |
|
CHECK HARNESS AND CONNECTOR (IGCT VOLTAGE)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the front luggage compartment trim cover Click here.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
| *a | Component with harness connected (No. 2 Hybrid Battery Pack Wire Connector) |
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
Note
Turning the power switch on (IG) with the service grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Install the front luggage compartment trim cover.
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR (BATTERY VOLTAGE SENSOR POWER SOURCE CIRCUIT) |
| OK |
|
CHECK HARNESS AND CONNECTOR (BATTERY VOLTAGE SENSOR - HYBRID BATTERY JUNCTION BLOCK ASSEMBLY)
Note
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the upper hybrid battery cover sub-assembly Click here.
Disconnect the z22 battery current sensor connector from the hybrid battery junction block assembly.
Disconnect the z21 battery voltage sensor connector.
| *a | Rear view of wire harness connector (to Battery Voltage Sensor) |
| *b | Front view of wire harness connector (to Hybrid Battery Junction Block Assembly) |
Measure the resistance according to the value(s) in the tables below.
| Standard Resistance (Check for Open) | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| Standard Resistance (Check for Short) | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Note
When taking a measurement with a tester, do not apply excessive force to the tester probe to avoid damaging the holder.
Tech Tips
Because the battery harness is not available as a supply part, if the harness cannot be repaired, replace the HV battery.
Reconnect the z21 battery voltage sensor connector.
Reconnect the z22 battery current sensor connector to the hybrid battery junction block assembly.
Install the upper hybrid battery cover sub-assembly.
| NG |
|
REPLACE HARNESS OR CONNECTOR (BATTERY CURRENT SENSOR) |
| OK |
|
CHECK BATTERY VOLTAGE SENSOR (VIB VOLTAGE)
Note
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the upper hybrid battery cover sub-assembly Click here.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
| *a | Component with harness connected (Battery Voltage Sensor) |
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
Note
Turning the power switch on (IG) with the service grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Install the upper hybrid battery cover sub-assembly.
| NG |
|
REPLACE BATTERY VOLTAGE SENSOR Click here |
| OK |
|
CHECK BATTERY VOLTAGE SENSOR (BATTERY CURRENT SENSOR OUTPUT VOLTAGE)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the upper hybrid battery cover sub-assembly. Click here.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
| *a | Component with harness connected (Battery Voltage Sensor) |
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
Note
Turning the power switch on (IG) with the service grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Install the upper hybrid battery cover sub-assembly.
| OK |
|
REPLACE BATTERY VOLTAGE SENSOR Click here |
| NG |
|
REPLACE HYBRID BATTERY JUNCTION BLOCK ASSEMBLY Click here |