| Item | Specified Condition |
|---|---|
| Valve opening temperature | 80 to 84°C (176 to 183°F) |
| Valve lift | 8.0 mm (0.315 in.) or more at 95°C (203°F) |
| Item | Condition | Specified Condition | |
|---|---|---|---|
| Cooling fan motor | for 100W+100W Type | when the battery is connected to the fan motor connector | 4.5 to 10.5 A at 20°C (68°F) |
| for 200W+200W Type | 13.0 to 19.0 A at 20°C (68°F) | ||
| No. 2 cooling fan motor | for 100W+100W Type | when the battery is connected to the No.2 fan motor connector | 4.5 to 10.5 A at 20°C (68°F) |
| for 200W+200W Type | 13.0 to 19.0 A at 20°C (68°F) | ||
| Condition | Specified Condition |
|---|---|
| Standard valve (for brand-new cap) |
94 to 122 kPa (1.0 to 1.2 kgf/cm2, 13.6 to 17.7 psi) |
| Minimum standard valve (for used cap) |
79 kPa (0.8 kgf/cm2, 11.4 psi) |
| Item | Tester Connection | Specified Condition |
|---|---|---|
| Fan No. 1 relay | 3 - 5 | 10 kΩ or higher (Battery voltage is not applied between terminals 1 and 2) |
| 3 - 5 | Below 1 Ω (Battery voltage is applied between terminals 1 and 2) |