HEATER WATER PUMP(for 2AR-FSE) INSTALLATION

PROCEDURE


  1. INSTALL HEATER BRACKET


    1. Install the heater bracket with the 2 bolts.

      Torque:
      9.8 N*m  { 100 kgf*cm, 87 in.*lbf }
  2. INSTALL HEATER WATER PUMP ASSEMBLY


    1. A000SPBE02
      Text in Illustration
      *1 Paint Mark (Orange)
      *2 Paint Mark (Yellow)
      *a Clip Installation Angle +/- 15 °

      Connect the heater water inlet hose A and heater water inlet hose B to the heater water pump assembly and slide the 2 clips to secure the 2 hoses as shown in the illustration.

      Note

      Do not apply excessive force to the heater water inlet hose.

    2. Install the heater water pump assembly with the 2 bolts.

      Torque:
      9.8 N*m  { 100 kgf*cm, 87 in.*lbf }
    3. Attach the harness clamp and connect the connector.

  3. ADD ENGINE COOLANT

    Click here

  4. INSPECT FOR COOLANT LEAK

    Click here

  5. INSTALL ENGINE UNDER COVER

    Click here