PROCEDURE
CHECK AIR CONDITIONING PRESSURE SENSOR
| *a | Front view of wire harness connector (to A/C pressure Sensor ) |
Check the wire harness.
Disconnect the connector from the air conditioning pressure sensor.
Measure the resistance of the wire harness side connector.
| Standard Resistance | ||||
|---|---|---|---|---|
|
| *a | Component with harness connected (Air Conditioner Amplifier Assembly) |
| *b | Voltage |
| *c | Refrigerant Pressure |
Check the air conditioning pressure sensor.
Set the manifold gauge.
Connect the connector to the pressure sensor.
Warm up compressor.
A/C switch is turned ON.
Measure the resistance according to the value(s) in the table below.
| Standard Voltage | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Note
Check from the rear of the connector while it is connected to the air conditioning amplifier.
Tech Tips
Because the air conditioning pressure sensor connector is waterproof and can not be checked, check the air conditioning amplifier assembly. Also, if the measurement is less than 1 V, open-circuit of the harness may occur.
The specified condition is the value included in the pressure deviation.
If the result is not as specified, replace the air conditioning pressure sensor.