CAUTION / NOTICE / HINT
Note
Set to recirculation mode before removing the No. 1 damper servo sub-assembly.
PROCEDURE
REMOVE AIR CONDITIONING UNIT
REMOVE BLOWER ASSEMBLY
| *1 | Drain Hose |
Remove the screw.
Detach the 3 claws and remove the blower assembly.
Disconnect the drain hose.