RELAY ON-VEHICLE INSPECTION

PROCEDURE


  1. INSPECT LH LIGHT RELAY


    1. A000SEYE38

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3 - 5 Battery voltage not applied to terminals 1 and 2 10 kΩ or higher
      Battery voltage applied to terminals 1 and 2 Below 1 Ω

      If the result is not as specified, replace the LH light relay.

  2. INSPECT RH LIGHT RELAY


    1. A000SEYE38

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3 - 5 Battery voltage not applied to terminals 1 and 2 10 kΩ or higher
      Battery voltage applied to terminals 1 and 2 Below 1 Ω

      If the result is not as specified, replace the RH light relay.