2AR-FSE HYBRID / BATTERY CONTROL SERVICE DATA

Reservoir Tank Cap (for Inverter)
Item Specified Condition
Standard value (for brand-new cap)

94 to 122 kPa (1.0 to 1.2 kgf/cm2, 13.6 to 17.7 psi)

Minimum standard value (for used cap)

94 kPa (1.0 kgf/cm2, 13.6 psi)

Relay
Item Tester Connection Specified Condition

IGCT relay

Resistance

3 - 5

10 kΩ or higher

(Auxiliary battery voltage is not applied across terminals 1 and 2)

3 - 5

Below 1 Ω

(Auxiliary battery voltage is applied across terminals 1 and 2)

INV W/ PMP relay

Resistance

3 - 5

10 kΩ or higher

(Auxiliary battery voltage is not applied across terminals 1 and 2)

3 - 5

Below 1 Ω

(Auxiliary battery voltage is applied across terminals 1 and 2)

Hybrid Battery Junction Block

SMRB

Resistance

(+) connector - (+) terminal

10 kΩ or higher

(Auxiliary battery voltage is not applied between terminals 4 (SMRB) and 2 (GND))

(+) connector - (+) terminal

Below 1 Ω

(Auxiliary battery voltage is applied between terminals 4 (SMRB) and 2 (GND))

4 (SMRB) - 2 (GND) 20.6 to 40.8 Ω at -40 to 176°F (-40 to 80°C)

SMRG

Resistance

(-) connector - (-) terminal

10 kΩ or higher

(Auxiliary battery voltage is not applied between terminals 1 (SMRG) and 2 (GND))

(-) connector - (-) terminal

Below 1 Ω

(Auxiliary battery voltage is applied between terminals 1 (SMRG) and 2 (GND))

1 (SMRG) - 2 (GND) 20.6 to 40.8 Ω at -40 to 176°F (-40 to 80°C)

SMRP

Resistance

(-) connector - (-) terminal

10 kΩ or higher

(Auxiliary battery voltage is not applied between terminals 3 (SMRP) and 2 (GND))

(-) connector - (-) terminal

28.5 to 31.5 Ω

(Auxiliary battery voltage is applied between terminals 3 (SMRP) and 2 (GND))

3 (SMRP) and 2 (GND) 140 to 290 Ω at -40 to 176°F (-40 to 80°C)
Combination Switch Assembly

EV Drive Mode Switch (Pattern Select Switch Assembly)

Resistance

I48-4 (S) - I48-1 (E)

Below 1 Ω

(EV drive mode switch (pattern select switch assembly) being pushed and held)

I48-4 (S) - I48-1 (E)

10 kΩ or more

(EV drive mode switch (pattern select switch assembly) not pushed)

Service Plug Grip
Service plug grip - Below 1 Ω