FRONT POWER SEAT CONTROL SYSTEM Front Power Seat does not Operate with Front Power Seat Switch

DESCRIPTION

When a signal is input into the front power seat switch (seat ECU), the ECU manages the signals received from the front power seat switch LH and RH, and operates each motor. When 2 or more signals are input, the motors only operate when the signals are from the slide switch and reclining switch.

WIRING DIAGRAM

A000W7RE08
A000W7RE05

PROCEDURE


  1. INSPECT FUSE


    1. Remove the D P/SEAT and D MPX-B 1 fuses from the main body ECU.

    2. Remove the P P/SEAT 1 and P MPX-B fuses from the passenger side junction block.

    3. Measure the resistance according to the value(s) in the table below.

      Standard resistance
      Tester Connection Condition Specified Condition
      D P/SEAT fuse Always Below 1 Ω
      D MPX-B 1 fuse Always Below 1 Ω
      P P/SEAT 1 fuse Always Below 1 Ω
      P MPX-B fuse Always Below 1 Ω

    NG
    OK
  2. CHECK HARNESS AND CONNECTOR (FRONT POWER SEAT SWITCH - BATTERY AND BODY GROUND)


    1. A000UEXE02

      for Driver side:


      1. Disconnect the e45*1, e46*1, e78*2 and e79*2 switch connectors.

      2. Measure the voltage according to the value(s) in the table below.

        Standard voltage
        for LHD
        Tester Connection Condition Specified Condition
        e45-7 (+B) - Body ground Always 11 to 14 V
        e46-4 (SYSB) - Body ground Always 11 to 14 V
        for RHD
        Tester Connection Condition Specified Condition
        e78-7 (+B) - Body ground Always 11 to 14 V
        e79-4 (SYSB) - Body ground Always 11 to 14 V
      3. Measure the resistance according to the value(s) in the table below.

        Standard resistance
        for LHD
        Tester Connection Condition Specified Condition
        e45-6 (GND) - Body ground Always Below 1 Ω
        for RHD
        Tester Connection Condition Specified Condition
        e78-6 (GND) - Body ground Always Below 1 Ω
    2. A000UDRE02

      for Passenger side:


      1. Disconnect the e18*1, e20*1, e71*2 and e72*2 switch connectors.

      2. Measure the voltage according to the value(s) in the table below.

        Standard voltage
        for LHD
        Tester Connection Condition Specified Condition
        e18-7 (+B) - Body ground Always 11 to 14 V
        e20-4 (SYSB) - Body ground Always 11 to 14 V
        for RHD
        Tester Connection Condition Specified Condition
        e71-7 (+B) - Body ground Always 11 to 14 V
        e72-4 (SYSB) - Body ground Always 11 to 14 V
      3. Measure the resistance according to the value(s) in the table below.

        Standard resistance
        for LHD
        Tester Connection Condition Specified Condition
        e18-6 (GND) - Body ground Always Below 1 Ω
        for RHD
        Tester Connection Condition Specified Condition
        e71-6 (GND) - Body ground Always Below 1 Ω

    OK
    NG