AIRBAG SYSTEM, Diagnostic DTC:B1830/57, B1831/57, B1832/57, B1833/57

DTC Code DTC Name
B1830/57 Short in Curtain Shield Squib RH Circuit
B1831/57 Open in Curtain Shield Squib RH Circuit
B1832/57 Short to GND in Curtain Shield Squib RH Circuit
B1833/57 Short to B+ in Curtain Shield Squib RH Circuit

DESCRIPTION

The curtain shield squib RH circuit consists of the center airbag sensor assembly and the curtain shield airbag RH.

The circuit instructs the SRS to deploy when deployment conditions are met.

These DTCs are recorded when a malfunction is detected in the curtain shield squib RH circuit.

DTC Code Detection Condition Trouble Area
B1830/57

One of the following conditions is met:


  • The center airbag sensor assembly receives a line short circuit signal 5 times in the curtain shield squib RH circuit during the primary check.

  • Curtain shield squib RH malfunction

  • Center airbag sensor assembly malfunction


  • Floor wire

  • Curtain shield airbag assembly RH (Curtain shield squib RH)

  • Center airbag sensor assembly

B1831/57

One of the following conditions is met:


  • The center airbag sensor assembly receives an open circuit signal in the curtain shield squib RH circuit for 2 seconds.

  • Curtain shield squib RH malfunction

  • Center airbag sensor assembly malfunction


  • Floor wire

  • Curtain shield airbag assembly RH (Curtain shield squib RH)

  • Center airbag sensor assembly

B1832/57

One of the following conditions is met:


  • The center airbag sensor assembly receives a short circuit to ground signal in the curtain shield squib RH circuit for 0.5 seconds.

  • Curtain shield squib RH malfunction

  • Center airbag sensor assembly malfunction


  • Floor wire

  • Curtain shield airbag assembly RH (Curtain shield squib RH)

  • Center airbag sensor assembly

B1833/57

One of the following conditions is met:


  • The center airbag sensor assembly receives a short circuit to B+ signal in the curtain shield squib RH circuit for 0.5 seconds.

  • Curtain shield squib RH malfunction

  • Center airbag sensor assembly malfunction


  • Floor wire

  • Curtain shield airbag assembly RH (Curtain shield squib RH)

  • Center airbag sensor assembly

WIRING DIAGRAM

A000VW5E47
*a Curtain Shield Squib RH
*b Center Airbag Sensor Assembly

CAUTION / NOTICE / HINT

Note


  • After turning the power switch OFF, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work Click here.

  • When disconnecting the cable from the negative (-) auxiliary battery terminal while performing repairs, some systems need to be initialized after the cable is reconnected Click here.

Tech Tips


  • Perform the simulation method by selecting "check mode" (signal check) with the intelligent tester Click here.

  • After selecting "check mode" (signal check), perform the simulation method by wiggling each connector of the airbag system or driving the vehicle on various types of roads Click here.

PROCEDURE


  1. CHECK CURTAIN SHIELD AIRBAG RH (CURTAIN SHIELD SQUIB RH)

    A000ULYE03
    *1 Curtain Shield Squib RH
    *2 Center Airbag Sensor Assembly
    *3 Front view of wire harness connector: (to Curtain Shield Squib RH)
    *4 Connector C

    1. Turn the power switch OFF.

    2. Disconnect the negative (-) terminal cable from the auxiliary battery, and wait for at least 90 seconds.

    3. Disconnect the connector from the curtain shield airbag RH.

    4. Connect the white wire side of SST (resistance: 2.1 Ω) to connector C.

      CAUTION:

      Never connect the tester to the curtain shield airbag RH (curtain shield squib RH) for measurement, as this may lead to a serious injury due to airbag deployment.

      Note


      • Do not forcibly insert SST into the terminals of the connector when connecting SST.

      • Insert SST straight into the terminals of the connector.

      SST
      09843-18061
    5. Connect the negative (-) terminal cable to the auxiliary battery, and wait for at least 2 seconds.

    6. Turn the power switch ON (IG), and wait for at least 60 seconds.

    7. Clear the DTCs Click here.

    8. Turn the power switch OFF.

    9. Turn the power switch ON (IG), and wait for at least 60 seconds.

    10. Check for DTCs Click here.

      OK
      DTC B1830, B1831, B1832 or B1833 is not output.

      Tech Tips

      Codes other than DTC B1830, B1831, B1832 and B1833 may be output at this time, but they are not related to this check.


    OK
    NG
  2. CHECK CONNECTOR


    1. Turn the power switch OFF.

    2. Disconnect the negative (-) terminal cable from the auxiliary battery, and wait for at least 90 seconds.

    3. Disconnect SST from connector C.

    4. Check that the floor wire connector (on the curtain shield airbag RH side) is not damaged.

      OK
      The lock button is not disengaged, or the claw of the lock is not deformed or damaged.

    NG
    OK
  3. CHECK FLOOR WIRE (CURTAIN SHIELD SQUIB RH CIRCUIT)

    A000X1CE03

    1. Disconnect the connectors from the center airbag sensor assembly.

    2. Connect the negative (-) terminal cable to the auxiliary battery, and wait for at least 2 seconds.

    3. Turn the power switch ON (IG).

    4. Measure the voltage according to the value(s) in the table below.

      Standard voltage
      Tester Connection Switch Condition Specified Condition
      R17-1 (ICR+) - Body ground Power switch ON (IG) Below 1 V
      R17-2 (ICR-) - Body ground Power switch ON (IG) Below 1 V
    5. Turn the power switch OFF.

    6. Disconnect the negative (-) terminal cable from the auxiliary battery, and wait for at least 90 seconds.

    7. Measure the resistance according to the value(s) in the table below.

      Standard resistance
      Tester Connection Condition Specified Condition
      R17-1 (ICR+) - R17-2 (ICR-) Always Below 1 Ω
    8. Release the activation prevention mechanism built into connector B Click here.

    9. Measure the resistance according to the value(s) in the table below.

      Standard resistance
      Tester Connection Condition Specified Condition
      R17-1 (ICR+) - R17-2 (ICR-) Always 1 MΩ or higher
      R17-1 (ICR+) - Body ground Always 1 MΩ or higher
      R17-2 (ICR-) - Body ground Always 1 MΩ or higher

    NG
    OK
  4. CHECK CENTER AIRBAG SENSOR ASSEMBLY

    A000WGIE90
    *1 Center Airbag Sensor Assembly
    *2 Curtain Shield Squib RH

    1. Connect the connectors to the curtain shield airbag RH and the center airbag sensor assembly.

    2. Connect the negative (-) terminal cable to the auxiliary battery, and wait for at least 2 seconds.

    3. Turn the power switch ON (IG), and wait for at least 60 seconds.

    4. Clear the DTCs Click here.

    5. Turn the power switch OFF.

    6. Turn the power switch ON (IG), and wait for at least 60 seconds.

    7. Check for DTCs Click here.

      OK
      DTC B1830, B1831, B1832 or B1833 is not output.

      Tech Tips

      Codes other than DTC B1830, B1831, B1832 and B1833 may be output at this time, but they are not related to this check.


    OK
    NG