DESCRIPTION
The display image signal from the multi-media module receiver assembly is sent to the accessory meter assembly using a digital communication cable.
WIRING DIAGRAM
PROCEDURE
CHECK HARNESS AND CONNECTOR
Check if the digital communication cable connectors between the multi-media module receiver assembly and the accessory meter assembly have any connection problems Click here.
| OK |
|---|
| There is no connection problems. |
| NG |
|
REMOVE CONNECTION PROBLEM (GVIF CABLE) |
| OK |
|
CHECK HARNESS AND CONNECTOR (GVIF CABLE)
Remove the GVIF cable from the multi-media module receiver assembly and accessory meter assembly.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| NG |
|
REPLACE HARNESS AND CONNECTOR (GVIF CABLE) |
| OK |
|
CHECK ACCESSORY METER ASSEMBLY
Replace the accessory meter assembly with a new or known good one Click here.
Check that the screen display is normal.
| OK |
|---|
| Screen display is normal. |
| OK |
|
END (ACCESSORY METER ASSEMBLY IS DEFECTIVE) |
| NG |
|
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE Click here |