FREEZE FRAME DATA
Connect the intelligent tester to the DLC3.
Turn the power switch ON (IG) and check the freeze frame data by following the prompts on the intelligent tester screen.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Tilt Position | Current tilt position data / min.: 0, max.: 65535 | 28672 to 36864 | - |
| Telesco Position | Current telescopic position data / min.: 0, max.: 65535 | 28672 to 36864 | - |
| Tilt Return Position | Memorized tilt return position data / min.: 0, max.: 65535 | 28672 to 36864 | - |
| Telesco Return Position | Memorized telescopic return position data / min.: 0, max.: 65535 | 28672 to 36864 | - |
| Tilt Up Switch | Input state of tilt up by manual switch / ON or OFF | ON: Tilt up is activated by manual switch OFF: Tilt up is not activated by manual switch |
- |
| Tilt Up SW (CAN) | Input state of tilt up by manual switch / ON or OFF | ON: Tilt up is activated by manual switch OFF: Tilt up is not activated by manual switch |
- |
| Tilt Down Switch | Input state of tilt down by manual switch / ON or OFF | ON: Tilt down is activated by manual switch OFF: Tilt down is not activated by manual switch |
- |
| Tilt Down SW (CAN) | Input state of tilt down by manual switch / ON or OFF | ON: Tilt down is activated by manual switch OFF: Tilt down is not activated by manual switch |
- |
| Telesco Short Switch | Input state of telescopic short by manual switch / ON or OFF | ON: Telescopic short is activated by manual switch OFF: Telescopic short is not activated by manual switch |
- |
| Telesco Short SW (CAN) | Input state of telescopic short by manual switch / ON or OFF | ON: Telescopic short is activated by manual switch OFF: Telescopic short is not activated by manual switch |
- |
| Telesco Long Switch | Input state of telescopic long by manual switch / ON or OFF | ON: Telescopic long is activated by manual switch OFF: Telescopic long is not activated by manual switch |
- |
| Telesco Long SW (CAN) | Input state of telescopic long by manual switch / ON or OFF | ON: Telescopic long is activated by manual switch OFF: Telescopic long is not activated by manual switch |
- |
| T&T Manual SW Data | Voltage data of manual switch / min.: 0.00 V, max.: 4.99 V | - | - |
| Power Source Voltage | Voltage data of power supply / min.: 0.00 V, max.: 19.99 V | Actual power supply voltage 11 to 14 V |
- |
| Freeze Speed Info | Vehicle speed data / min: 0 km/h (0 mph), max.: 255 km/h (158 mph) | Actual vehicle speed | - |
| IG Switch (CAN) | Communication state of power switch / ON or OFF | ON: Communication is normal OFF: Communication is interrupted |
- |
| IG Switch | Input state of engine switch / ON or OFF | ON: Input signal is normal OFF: Input signal is interrupted |
- |
| Key Switch(CAN) | Communication state of key switch / ON or OFF | - | - |
| Key Code Confirm (CAN) | Communication state of key code confirmation signal / ON or OFF | ON: Communication is normal OFF: Communication is interrupted |
- |
| Receive from Meter | Communication state of combination meter signal / OK or Interpt | OK: Communication is normal Interpt: Communication is interrupted |
- |
| Receive from Seat ECU | Communication state of seat ECU signal / OK or Interpt | OK: Communication is normal Interpt: Communication is interrupted |
- |
| Receive from Combi | Communication state of combination switch ECU signal / OK or Interpt | OK: Communication is normal Interpt: Communication is interrupted |
- |
| J/B | Communication state of main body ECU signal / OK or Interpt | OK: Communication is normal Interpt: Communication is interrupted |
- |
| B/B | Communication state of optional after parts ECU signal / OK or Interpt | OK: Communication is normal Interpt: Communication is interrupted |
- |
| Driver Seat Buckle SW | Driver side buckle switch signal / Set, Unset or Unknown | Set: Driver side seat belt is fastened Unset: Driver side seat belt is unfastened |
- |
| The Number of DTCs | Number of diagnosis codes / min.: 0, max.: 255 | Actual number of diagnosis codes | - |