HEIGHT CONTROL SENSOR(for Front LH) INSPECTION

PROCEDURE


  1. INSPECT FRONT HEIGHT CONTROL SENSOR SUB-ASSEMBLY LH

    A000Z1OE04

    1. Connect 3 dry batteries of 1.5 V in series.

    2. Connect terminal 3 to the batteries' positive (+) terminal, and terminal 1 to the batteries' negative (-) terminal.

    3. Inspect the change in voltage when the height control sensor link is slowly moved up and down.


      1. Measure the voltage according to the value(s) in the table below.

        Standard voltage
        Tester Connection Condition Specified Condition
        2 - 1 Max. HI Approx. 4.1 V
        Normal Approx. 2.25 V
        Min. LO Approx. 0.45 V

        Note


        • Do not apply a voltage of more than 6 V.

        • Do not drop the height control sensor. If it is dropped, replace it with a new one.

        If the result is not as specified, replace the front height control sensor sub-assembly LH.